Literature DB >> 19298877

Sensitive determination of salicylate and benzophenone type UV filters in water samples using solid-phase microextraction, derivatization and gas chromatography tandem mass spectrometry.

N Negreira1, I Rodríguez, M Ramil, E Rubí, R Cela.   

Abstract

A sensitive procedure for the determination of three UV filters: ethylhexyl salicylate (EHS), 3,3,5-trimethylcyclohexyl salicylate (Homosalate, HMS), 2-hydroxy-4-methoxybenzophenone (BP-3) and two related hydroxylated benzophenones (2,4-dihydroxybenzophenone, BP-1 and 2,2'-dihydroxy-4-methoxybenzophenone, BP-8) in water samples is presented. Analytes were first concentrated on the coating of a solid-phase microextraction (SPME) fibre, on-fibre silylated and then determined using gas chromatography combined with tandem mass spectrometry (GC-MS/MS). Factors affecting the performance of extraction and derivatization steps are thoroughly evaluated and their effects on the yield of the sample preparation discussed. Under final working conditions, a PDMS-DVB coated SPME fibre was exposed directly to 10 mL of water, adjusted at pH 3, for 30 min. After that, the fibre was placed in the headspace (HS) of a 1.5 mL vial containing 20 microL of N-methyl-N-(trimethylsilyl)-trifluoroacetamide (MSTFA). On-fibre silylation of hydroxyl groups contained in the structure of target compounds was performed at 45 degrees C for 10 min. The whole sample preparation process was completed in 40 min, providing limits of quantification from 0.5 to 10 ng L(-1) and acceptable precision (RSDs under 13%) for samples spiked at different concentrations. All compounds could be accurately determined in river and treated wastewater (relative recoveries from 89 to 115%) using standards in ultrapure water, whereas standard addition is recommended to quantify their levels in untreated wastewater. Analysis of wastewater revealed the systematic presence of BP-3 and BP-1 in raw samples with maximum concentrations close to 500 and 250 ng L(-1), respectively.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19298877     DOI: 10.1016/j.aca.2009.02.015

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  The occurrence of UV filters in natural and drinking water in São Paulo State (Brazil).

Authors:  Claudia Pereira da Silva; Elissandro Soares Emídio; Mary Rosa Rodrigues de Marchi
Journal:  Environ Sci Pollut Res Int       Date:  2015-08-18       Impact factor: 4.223

2.  Differentiation of regioisomeric aromatic ketocarboxylic acids by positive mode atmospheric pressure chemical ionization collision-activated dissociation tandem mass spectrometry in a linear quadrupole ion trap mass spectrometer.

Authors:  Lucas M Amundson; Benjamin C Owen; Vanessa A Gallardo; Steven C Habicht; Mingkun Fu; Ryan C Shea; Allen B Mossman; Hilkka I Kenttämaa
Journal:  J Am Soc Mass Spectrom       Date:  2011-02-12       Impact factor: 3.109

3.  Determination of Benzophenones in Water and Cosmetics Samples: A Comparison of Solid-Phase Extraction and Microextraction by Packed Sorbent Methods.

Authors:  Grażyna Wejnerowska; Izabela Narloch
Journal:  Molecules       Date:  2021-11-16       Impact factor: 4.411

4.  [Research progress on lyophilization for pretreatment of emerging organic contaminants in environmental samples].

Authors:  Yiqing Zhang; Shanshan Guo; Qian Sun
Journal:  Se Pu       Date:  2021-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.