Literature DB >> 19298022

Early clinical experience with the use of the Birmingham hip resurfacing system.

German A Marulanda1, M Stephen Wilson, Paul Edwards, Steve Raterman.   

Abstract

This study reviews the early clinical experience with the Birmingham Hip resurfacing system (Smith & Nephew, Memphis, Tenn) in the United States since its approval by the FDA. A total of 230 patients were followed for a mean of 16 months (range, 6 months). There was a significant improvement in the mean preoperative Oxford hip score at the latest follow-up (44 points [range, 30-58 points] to 17 points [range, 12-28 points]). The most commonly used femoral component was 50 mm, and the mean duration of the procedures was 95 minutes (range, 65-180 min). there were 3 revisions (1.3%). Early results are favorable. As with any device, there is a continuing need for longterm monitoring and large-scale epidemiologic surveillance.

Entities:  

Mesh:

Year:  2008        PMID: 19298022

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  5 in total

1.  Revision rate of Birmingham Hip Resurfacing arthroplasty: comparison of published literature and arthroplasty register data.

Authors:  Reinhard Schuh; Daniel Neumann; Rauend Rauf; Jochen Hofstaetter; Nikolaus Boehler; Gerold Labek
Journal:  Int Orthop       Date:  2012-02-22       Impact factor: 3.075

Review 2.  Hip resurfacing: a systematic review of literature.

Authors:  Régis Pailhé; Akash Sharma; Nicolas Reina; Etienne Cavaignac; Philippe Chiron; Jean-Michel Laffosse
Journal:  Int Orthop       Date:  2012-10-26       Impact factor: 3.075

3.  Poor outcome of revised resurfacing hip arthroplasty.

Authors:  Richard N de Steiger; Lisa N Miller; Gareth H Prosser; Stephen E Graves; David C Davidson; Tyman E Stanford
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

Review 4.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

Review 5.  Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements--The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis.

Authors:  Aleksi Reito; Olli Lainiala; Petra Elo; Antti Eskelinen
Journal:  PLoS One       Date:  2016-03-01       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.