Literature DB >> 19297207

Whole-body MR angiography with body coil acquisition at 3 T in patients with peripheral arterial disease using the contrast agent gadofosveset trisodium.

Yousef W Nielsen1, Jonas P Eiberg, Vibeke B Løgager, Marc A Hansen, Torben V Schroeder, Henrik S Thomsen.   

Abstract

RATIONALE AND
OBJECTIVES: Whole-body magnetic resonance angiography (WB-MRA) at 3 T with body coil acquisition has not previously been investigated. In this study, WB-MRA was performed in this manner using the blood pool contrast agent gadofosveset trisodium.
MATERIALS AND METHODS: Eleven consecutive patients (five men, six women) with symptomatic peripheral arterial disease (two with critical limb ischemia, nine with claudication) were examined. Conventional digital subtraction angiography (DSA) of the aorta and the inflow and runoff arteries was used as the reference method. WB-MRA was performed using four slightly overlapping stations covering the arteries from the neck to the ankles. The arterial system was divided into 42 segments that were analyzed for the presence of significant arterial disease (> or =50% luminal narrowing or occlusion) by two blinded observers.
RESULTS: Sensitivities for detecting a significant arterial lesion with WB-MRA using gadofosveset as the contrast agent were 0.66 (95% confidence interval [CI], 0.49-0.79) and 0.68 (95% CI, 0.52-0.81) for the two observers. Specificities were 0.82 (95% CI, 0.74-0.88) and 0.93 (95% CI, 0.87-0.96), respectively. Intermodality agreement between WB-MRA and DSA was moderate to good, with overall kappa values of 0.44 (95% CI, 0.29-0.59) and 0.63 (95% CI, 0.5-0.77) for the two observers. Interobserver agreement for WB-MRA was good, at kappa = 0.60 (95% CI, 0.50-0.71).
CONCLUSION: WB-MRA at 3 T with body coil acquisition in patients with peripheral arterial disease showed good reproducibility but only moderate to good agreement with DSA. Further assessment of the method's clinical application is warranted.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19297207     DOI: 10.1016/j.acra.2008.12.018

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  3 in total

1.  Improved quality and diagnostic confidence achieved by use of dose-reduced gadolinium blood-pool agents for time-resolved intracranial MR angiography.

Authors:  S Dehkharghani; J Kang; A M Saindane
Journal:  AJNR Am J Neuroradiol       Date:  2013-08-22       Impact factor: 3.825

2.  Improved detection of in-stent restenosis by blood pool agent-enhanced, high-resolution, steady-state magnetic resonance angiography.

Authors:  Christina M Plank; Florian Wolf; Herbert Langenberger; Michael Weber; Dietrich Beitzke; Alfred Stadler; Martin Schillinger; Johannes Lammer; Christian Loewe
Journal:  Eur Radiol       Date:  2011-05-10       Impact factor: 5.315

3.  MR angiography of collateral arteries in a hind limb ischemia model: comparison between blood pool agent Gadomer and small contrast agent Gd-DTPA.

Authors:  Karolien Jaspers; Bas Versluis; Tim Leiner; Petra Dijkstra; Marlies Oostendorp; Jolanda M van Golde; Mark J Post; Walter H Backes
Journal:  PLoS One       Date:  2011-01-26       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.