Literature DB >> 19296193

Non-cardiac implantable electrical devices: brief review and implications for anesthesiologists.

Lashmi Venkatraghavan1, Vinod Chinnapa, Philip Peng, Richard Brull.   

Abstract

PURPOSE: Patients with implanted electrical devices (IEDs) are vulnerable to electromagnetic interference (EMI) from electrical equipment used in the perioperative environment. As the indications for non-cardiac IEDs increase, so too does the likelihood of anesthesiologists encountering such patients who present for surgery. This article reviews the important anesthetic considerations for patients with implanted non-cardiac electrical devices. SOURCE: We searched Medline (1980 to December 2008) and Embase (1980 to December 2008) and reviewed all relevant manuscripts regarding non-cardiac IEDs and anesthesia. PRINCIPAL
FINDINGS: There are numerous non-cardiac IEDs currently in use, including deep brain stimulators, vagal nerve stimulators, gastric stimulators, phrenic nerve stimulators, sacral nerve stimulators, and bone stimulators. A key goal in the perioperative management of these patients is to reduce the risk of adverse events resulting from device interactions with electrocautery, external emergency cardiac defibrillation, peripheral nerve stimulation, neuraxial anesthesia, and magnetic resonance imaging. We offer a general management strategy for patients with IEDs presenting for surgery.
CONCLUSIONS: In the absence of available anesthesia management guidelines regarding non-cardiac IEDs in the perioperative setting, anesthesiologists should appreciate the basic principles pertaining to IEDs to ensure appropriate risk reduction strategies in order to enhance patient safety.

Entities:  

Mesh:

Year:  2009        PMID: 19296193     DOI: 10.1007/s12630-009-9056-3

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  3 in total

Review 1.  [Anesthesiological aspects of deep brain stimulation : special features of implementation and dealing with brain pacemaker carriers].

Authors:  M Seemann; N Zech; M Lange; J Hansen; E Hansen
Journal:  Anaesthesist       Date:  2013-07       Impact factor: 1.041

2.  Ultrathin Graphene-Protein Supercapacitors for Miniaturized Bioelectronics.

Authors:  Islam M Mosa; Ajith Pattammattel; Karteek Kadimisetty; Paritosh Pande; Maher F El-Kady; Gregory W Bishop; Marc Novak; Richard B Kaner; Ashis K Basu; Challa V Kumar; James F Rusling
Journal:  Adv Energy Mater       Date:  2017-05-09       Impact factor: 29.368

3.  Vagus Nerve Stimulation and External Defibrillation during Resuscitation; a Letter to Editor.

Authors:  Matthias Wittstock; Johannes Buchmann; Uwe Walter; Johannes Rösche
Journal:  Emerg (Tehran)       Date:  2018-04-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.