Literature DB >> 19295379

Efficacy and tolerability of nonpenetrating filtering surgery with and without implant in treatment of open angle glaucoma: a quantitative evaluation of the evidence.

Jin-Wei Cheng1, Rui-Li Wei, Ji-Ping Cai, You Li.   

Abstract

OBJECTIVE: To evaluate the efficacy and tolerability of nonpenetrating filtering surgery augmented with implant (NPFSI) compared with nonpenetrating filtering surgery without implant (NPFS) in the treatment of patients with open angle glaucoma.
METHODS: Pertinent studies were selected through extensive searches of the Cochrane Library, PubMed, Embase, and American Association of Ophthalmology (AAO) and Association for Research in Vision and Ophthalmology (ARVO) meeting abstracts. Seven controlled clinical trials meeting the predefined criteria were systematically reviewed by meta-analysis. The main outcome measures were percentage intraocular pressure (IOP) reduction, complete success rates, and qualified success rates. The pooled estimates were carried out in RevMan version 4.2 software.
RESULTS: The weighted mean difference of the percentage IOP reduction from baseline were 6.7% (95% confidence intervals: -3.8 to 17.2) when comparing NPFSI with NPFS. NPFSI was associated with numerically greater, but nonsignificant, IOP lowering efficacy than NPFS. The pooled risk differences comparing NPFSI with NPFS were 0.13 (-0.02 to 0.28) in complete success rate and 0.09 (-0.04 to 0.21) in qualified success rate. Numerically greater, but nonsignificant, proportions of NPFSI patients than NPFS patients achieved the target end point IOP. NPFSI resulted in the same incidences of postoperative complications as NPFS.
CONCLUSIONS: NPFSI was associated with equivalent efficacy to standard NPFS in lowering IOP. Comparable proportions of patients reached the IOP target with NPFSI and NPFS. Both surgeries were well tolerated.

Entities:  

Mesh:

Year:  2009        PMID: 19295379     DOI: 10.1097/IJG.0b013e3181812827

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  3 in total

1.  Laser Treatment to avoid Trabeculectomy and to recover the Aqueous Outflow after Iris Incarceration in a Patient with NPDS.

Authors:  Alfonso Vasquez Perez; Jorge Loscos Arenas; Julio De La Camara Hermoso
Journal:  J Curr Glaucoma Pract       Date:  2013-01-15

Review 2.  Systematic overview of the efficacy of nonpenetrating glaucoma surgery in the treatment of open angle glaucoma.

Authors:  Jin-Wei Cheng; Shi-Wei Cheng; Ji-Ping Cai; You Li; Rui-Li Wei
Journal:  Med Sci Monit       Date:  2011-07

3.  Deep Sclerectomy with Goniosynechiolysis Ab Interno for Chronic Glaucoma Associated with Peripheral Anterior Synechiae.

Authors:  Alireza Mirshahi; Peter Raak; Katharina Ponto; Bernhard Stoffelns; Katrin Lorenz; Gábor B Scharioth
Journal:  J Ophthalmol       Date:  2015-06-23       Impact factor: 1.909

  3 in total