Nitromatrix provides improved LC-MALDI signals and more protein identifications.

Petri Kouvonen1, Liam A McDonnell, Ron M A Heeren, Garry L Corthals.   

Abstract

The beneficial use of NC in MALDI-MS has previously been reported to provide better S/N and reproducibility as well as less alkali metal adducts. We have therefore investigated if additional beneficial properties of NC also existed for commonly employed proteomics-based LC-MALDI procedures. Specifically we studied the effects of NC as a matrix cofactor for prestructured sample supports (AnchorChip plates), and compared the performance with several alternative sample preparation methods recently reported in the literature. The work reported here describes a new method of mixing the NC-matrix solution with the LC-eluent prior to sample deposition and shows that a mixture of CHCA and NC in a complex solvent offers superior analytical results in several ways: most striking is the higher signal intensity, and that the signals last much longer, due to the robustness of the matrix formulation. We have tested the use of the nitromatrix on a single LC-MALDI preparation and found that at least ten reiterative analyses could be performed, resulting in total analysis times of more than 75 h (approximately 15 million laser shots). Consequently more than twice as many proteins could be identified than from a single analysis. This combination of longer, and stronger, MALDI signals provided an increase in the number of peptides, greater sequence coverage in MS/MS experiments and ultimately more confident peptide assignments.

Mesh:

Substances:

Year:  2009        PMID: 19294627     DOI: 10.1002/pmic.200800302

Source DB:  PubMed          Journal:  Proteomics        ISSN: 1615-9853            Impact factor:   3.984


  2 in total

1.  The Characterization of Laser Ablation Patterns and a New Definition of Resolution in Matrix Assisted Laser Desorption Ionization Imaging Mass Spectrometry (MALDI-IMS).

Authors:  Matthew B O'Rourke; Benjamin B A Raymond; Matthew P Padula
Journal:  J Am Soc Mass Spectrom       Date:  2017-03-13       Impact factor: 3.109

2.  The comparison of CHCA solvent compositions for improving LC-MALDI performance and its application to study the impact of aflatoxin B1 on the liver proteome of diabetes mellitus type 1 mice.

Authors:  Fuu-Jen Tsai; Shih-Yin Chen; Yu-Ching Liu; Hsin-Yi Liao; Chao-Jung Chen
Journal:  PLoS One       Date:  2017-07-24       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.