Literature DB >> 19293612

[Functional results of the parallel-plate technique for complex distal humerus fractures].

Ata Can Atalar1, Mehmet Demirhan, Ahmet Salduz, Onder Kiliçoğlu, Aksel Seyahi.   

Abstract

OBJECTIVES: We evaluated functional results of patients treated with open reduction and internal fixation with the parallel-plate technique for complex distal humerus fractures.
METHODS: Twenty-one patients (14 males, 7 females; mean age 47 years; range 16 to 85) underwent open reduction with olecranon osteotomy and internal fixation with the parallel-plate technique for distal humerus fractures accompanied by highly intra-articular or metaphyseal comminution (n=10), intra-articular comminution and osteoporosis (n=7), and intra-articular and metaphyseal comminution with bone loss (n=4). According to the AO classification, there were 12 C3, six C2, and three C1 type fractures. Eight patients had open fractures. The mean time to surgery was six days (range 1 to 17 days). Functional results were evaluated using the Mayo elbow performance score, Jupiter elbow score, and DASH (Disabilities of the Arm, Shoulder and Hand) score. The mean follow-up was 28 months (range 12 to 48 months).
RESULTS: The mean total range of motion was 90.2+/-31.1 degrees, flexion was 118.1+/-17.4 degrees, and extension was 27.8+/-17.4 degrees. The mean Mayo elbow performance score and DASH score were 86.1+/-12.6 and 7.6+/-9.5, respectively. According to the Jupiter elbow scores, the results were excellent in seven patients, good in 11 patients, moderate in two patients, and poor in one patient. Radiographically, solid union was achieved in all the patients. Heterotopic ossification of varying degrees was seen in seven patients, two of whom underwent resection of heterotopic ossification due to severe limitation of movement. Debridement was performed in one patient due to the development of deep infection. Chondrolysis of the elbow occurred in one patient. Patients with open fractures had significantly lower range of motion than those with closed fractures (p<0.05), but the Mayo elbow performance score and DASH score did not differ significantly in this respect (p>0.05).
CONCLUSION: Functional results are satisfactory in distal humerus fractures treated with stable osteosynthesis and parallel-plate technique that allow early active motion.

Entities:  

Mesh:

Year:  2009        PMID: 19293612     DOI: 10.3944/AOTT.2009.021

Source DB:  PubMed          Journal:  Acta Orthop Traumatol Turc        ISSN: 1017-995X            Impact factor:   1.511


  11 in total

Review 1.  [Intra-articular fractures of the distal humerus : aspects of fracture treatment in geriatric patients].

Authors:  T G Gerich
Journal:  Orthopade       Date:  2014-04       Impact factor: 1.087

Review 2.  Management of distal humerus fractures.

Authors:  Alexander Lauder; Marc J Richard
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-01-21

3.  Functional Results of Intercondylar Fractures of the Humerus Fixed with Dual Y-Plate; A Technical Note.

Authors:  Swagat Mahapatra; Vineet Thomas Abraham
Journal:  Bull Emerg Trauma       Date:  2017-01

4.  Intercondylar humerus fracture- parallel plating and its results.

Authors:  Sanjiv Kumar; Sudhir Singh; Dharmender Kumar; Neeraj Kumar; Reetu Verma
Journal:  J Clin Diagn Res       Date:  2015-01-01

5.  Functional Results of Communited Intra-articular Distal Humerus Fractures Treated with Bicolumnar Plating.

Authors:  Siddharth Rashmikant Virani; Sandeep Sonone; Aditya Anand Dahapute; Inayat Panda; Kunal Dwijen Roy
Journal:  J Clin Diagn Res       Date:  2017-04-01

6.  Combined use of minimal screw synthesis and external articulated fixation is effective for the management of supra-intercondyloid humeral fractures in the elderly? A retrospective study.

Authors:  Fabrizio Bienati; Alessandro Isola; Sebastiano Ortu; Luca Bonini; Rossella Sirianni; Antonio Capone; Mario Manca
Journal:  J Orthop       Date:  2022-09-27

7.  Evaluation of risk factors for stiffness after distal humerus plating.

Authors:  Onur Tunalı; Ali Erşen; Tuna Pehlivanoğlu; Serkan Bayram; Ata C Atalar; Mehmet Demirhan
Journal:  Int Orthop       Date:  2018-02-01       Impact factor: 3.075

8.  Analysis of Factors Affecting Return to Work After Surgical Treatment in Patients with AO Type C Distal Humerus Fractures.

Authors:  Mert Kumbaraci; Can Doruk Basa; Ali Turgut
Journal:  Indian J Orthop       Date:  2020-09-19       Impact factor: 1.251

9.  Controversies in the management of intra-articular fractures of distal humerus in adults.

Authors:  Sudhir Babhulkar; Sushrut Babhulkar
Journal:  Indian J Orthop       Date:  2011-05       Impact factor: 1.251

10.  Bicolumnar 90-90 plating of AO 13C type fractures.

Authors:  Cemal Kural; Ersin Ercin; Mehmet Erkilinc; Evren Karaali; Mustafa Gokhan Bilgili; Suleyman Altun
Journal:  Acta Orthop Traumatol Turc       Date:  2017-03-22       Impact factor: 1.511

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.