Literature DB >> 19291987

Monte Carlo radiation dose simulations and dosimetric comparison of the model 6711 and 9011 125I brachytherapy sources.

Mark J Rivard1.   

Abstract

Smaller diameter brachytherapy seeds for permanent interstitial implantation allow for use of smaller diameter implant needles. The use of smaller diameter needles may provide a lower incidence of healthy-tissue complications. This study determines the brachytherapy dosimetry parameters for the smaller diameter source (model 9011) and comments on the dosimetric comparison between this new source and the conventional brachytherapy seed (model 6711).

Mesh:

Substances:

Year:  2009        PMID: 19291987     DOI: 10.1118/1.3056463

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Assessment of targeting accuracy of a low-energy stereotactic radiosurgery treatment for age-related macular degeneration.

Authors:  Phillip J Taddei; Erik Chell; Steven Hansen; Michael Gertner; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

2.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  A directional 103Pd brachytherapy device: Dosimetric characterization and practical aspects for clinical use.

Authors:  Mark J Rivard
Journal:  Brachytherapy       Date:  2016-12-28       Impact factor: 2.362

4.  Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy.

Authors:  Payvand Taherparvar; Zeinab Fardi
Journal:  Nucl Med Mol Imaging       Date:  2021-01-11

5.  New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design.

Authors:  Evaggelos Pantelis; Panagiotis Papagiannis; Giorgos Anagnostopoulos; Dimos Baltas
Journal:  J Contemp Brachytherapy       Date:  2013-12-21

6.  Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd Seeds.

Authors:  H Rezaei; H Mostaghimi; A R Mehdizadeh
Journal:  J Biomed Phys Eng       Date:  2017-09-01

7.  The phylogeny of permanent prostate brachytherapy.

Authors:  Jesse N Aronowitz; Mark J Rivard
Journal:  J Contemp Brachytherapy       Date:  2013-06-28

8.  Monte Carlo study of a new I-125 brachytherapy prototype seed with a ceramic radionuclide carrier and radiographic marker.

Authors:  Lucas Paixão; Alessandro Facure; Ana Maria M Santos; Adriano Márcio dos Santos; Suely Epsztein Grynberg
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.