Literature DB >> 19291807

A novel chemiluminescent flow injection analysis of trace amounts of rutin by its inhibition of the luminol-hydrogen peroxide reaction catalyzed by tetrasulfonated colbalt phthalocyanine.

Qiyong Zhu1.   

Abstract

Based on the inhibition effect of rutin on the luminol-hydrogen peroxide chemiluminescence (CL) system catalyzed by tetrasulfonated colbalt phthalocyanine (CoTSPc), a sensitive flow-injection CL method has been developed for the determination of rutin. The CL reaction mechanism was carefully investigated by examining CL emission spectra, UV-visible spectra and variation of reaction conditions. It was found that there existed a linear relationship between CL intensity and the concentration of rutin in the range of 8.0 x 10(-9) to 1.0 x 10(-6) mol L(-1), and the detection limit is 3.8 x 10(-9) mol L(-1). This proposed method is sensitive, convenient and simple, and has been applied to the determination of rutin in commercial rutin tablets with satisfactory results. Copyright 2008 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19291807     DOI: 10.1002/bio.1108

Source DB:  PubMed          Journal:  Luminescence        ISSN: 1522-7235            Impact factor:   2.464


  2 in total

1.  A covalent triazine framework as an oxidase mimetic in the luminol chemiluminescence system: application to the determination of the antioxidant rutin.

Authors:  Haonan Tan; Yaxin Zhao; Xiaotong Xu; Yuan Sun; Yinhuan Li; Jianxiu Du
Journal:  Mikrochim Acta       Date:  2019-12-12       Impact factor: 5.833

2.  Effect of human and bovine serum albumin on kinetic chemiluminescence of Mn (III)-Tetrakis (4-sulfonatophenyl) porphyrin-luminol-hydrogen peroxide system.

Authors:  Sayed Yahya Kazemi; Seyed Mohammad Abedirad
Journal:  ScientificWorldJournal       Date:  2012-05-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.