Literature DB >> 1929132

Wound compression pads are of no value after local anaesthetic breast biopsy.

A J Johnstone1, A M Thompson, M Charles, T G John, J M Dixon.   

Abstract

In a randomised study of 120 patients undergoing breast biopsy, wound compression pads did not reduce the frequency of postoperative bruising or haematoma formation, and 12% of the 62 patients having pads had complaints regarding their use. Wound compression pads are of no value after local anaesthetic breast biopsy.

Entities:  

Mesh:

Year:  1991        PMID: 1929132      PMCID: PMC2499508     

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  5 in total

1.  Drainage or suture of the cavity after breast biopsy.

Authors:  N W Law; C D Johnson; P M Lamont; H Ellis
Journal:  Ann R Coll Surg Engl       Date:  1990-01       Impact factor: 1.891

2.  The advantage of adrenaline in local and general anaesthetic breast biopsy.

Authors:  J M Dixon; T J Crofts; C P Armstrong; D Lee; J A Wilson; A P Forrest
Journal:  J R Coll Surg Edinb       Date:  1983-09

3.  Comparison of general and local anaesthesia for biopsy of breast lumps.

Authors:  U Chetty; S J Nixon; R J Steele; A P Forrest
Journal:  J R Coll Surg Edinb       Date:  1983-01

Review 4.  Biopsy of the breast.

Authors:  J Philip; W G Harris
Journal:  Br J Hosp Med       Date:  1981-05

5.  Subcuticular skin closure following minor breast biopsy: Prolene is superior to polydioxanone (PDS)

Authors:  R J Aitken; E D Anderson; S Goldstraw; U Chetty
Journal:  J R Coll Surg Edinb       Date:  1989-06
  5 in total
  2 in total

1.  Provision and acceptability of day case breast biopsy: an audit of current practice.

Authors:  M S Coady; E A Benson; M N Hartley
Journal:  Ann R Coll Surg Engl       Date:  1993-07       Impact factor: 1.891

2.  Should breast biopsy cavities be drained?

Authors:  H W Warren; C D Griffith; L McLean; W J Angerson; B Kaye; M McElroy
Journal:  Ann R Coll Surg Engl       Date:  1994-01       Impact factor: 1.891

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.