Literature DB >> 19290667

Detection of extracellular H2O2 released from human liver cancer cells based on TiO2 nanoneedles with enhanced electron transfer of cytochrome c.

Yongping Luo1, Haiqing Liu, Qi Rui, Yang Tian.   

Abstract

The high conductive TiO(2) nanoneedles film is first employed as a support matrix for immobilizing model enzyme, cytochrome c (cyt c) to facilitate the electron transfer between redox enzymes and electrodes. Reversible and direct electron transfer of cyt c is successfully achieved at the nanostructured TiO(2) surface with the redox formal potential (E(0)') of 108.0 +/- 1.9 mV versus Ag|AgCl and heterogeneous electron transfer rate constant (k(s)) of 13.8 +/- 2.1 s(-1). Experimental data indicate that cyt c is stably immobilized onto the TiO(2) nanoneedles film and maintains inherent enzymatic activity toward H(2)O(2). On the basis of these results, the cyt c-TiO(2) nanocomposits film is capable of sensing H(2)O(2) at a suitable potential, 0.0 V (vs Ag|AgCl), where not only common anodic interferences like ascorbic acid, uric acid, 3,4-dihydroxyphenylacetic acid but also a cathodic interference, O(2), are effectively avoided. Besides high selectivity, the present biosensor for H(2)O(2) shows broad dynamic range and low detection limit. These remarkable analytical advantages, as well as the characteristic of TiO(2) nanoneedles film such as high conductivity, biocompatibility, and facile ability to miniaturize establishes a novel approach to detection of extracellular H(2)O(2) released from human liver cancer cells.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19290667     DOI: 10.1021/ac802721x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  16 in total

1.  Cancer biomarker profiling using nanozyme containing iron oxide loaded with gold particles.

Authors:  Victor Akpe; Muhammad J A Shiddiky; Tak H Kim; Christopher L Brown; Yusuke Yamauchi; Ian E Cock
Journal:  J R Soc Interface       Date:  2020-06-24       Impact factor: 4.118

Review 2.  Metal oxide nanoparticles in electrochemical sensing and biosensing: a review.

Authors:  Jaise Mariya George; Arun Antony; Beena Mathew
Journal:  Mikrochim Acta       Date:  2018-07-04       Impact factor: 5.833

Review 3.  Recent Advances in Electrochemical Sensing of Hydrogen Peroxide (H2O2) Released from Cancer Cells.

Authors:  Touqeer Ahmad; Ayesha Iqbal; Sobia Ahsan Halim; Jalal Uddin; Ajmal Khan; Sami El Deeb; Ahmed Al-Harrasi
Journal:  Nanomaterials (Basel)       Date:  2022-04-26       Impact factor: 5.719

4.  In-Line Analysis of Organ-on-Chip Systems with Sensors: Integration, Fabrication, Challenges, and Potential.

Authors:  Stefanie Fuchs; Sofia Johansson; Anders Ø Tjell; Gabriel Werr; Torsten Mayr; Maria Tenje
Journal:  ACS Biomater Sci Eng       Date:  2021-06-16

5.  Functionalized helical fibre bundles of carbon nanotubes as electrochemical sensors for long-term in vivo monitoring of multiple disease biomarkers.

Authors:  Liyuan Wang; Songlin Xie; Zhiyuan Wang; Fei Liu; Yifan Yang; Chengqiang Tang; Xiaoying Wu; Peng Liu; Yongjing Li; Hexige Saiyin; Shuang Zheng; Xuemei Sun; Fan Xu; Hongbo Yu; Huisheng Peng
Journal:  Nat Biomed Eng       Date:  2019-10-28       Impact factor: 25.671

6.  Preparation of a porous composite film for the fabrication of a hydrogen peroxide sensor.

Authors:  Mu-Yi Hua; Chun-Jen Chen; Hsiao-Chien Chen; Rung-Ywan Tsai; Wen Cheng; Chun-Lin Cheng; Yin-Chih Liu
Journal:  Sensors (Basel)       Date:  2011-05-31       Impact factor: 3.576

7.  Effects of Nanowire Length and Surface Roughness on the Electrochemical Sensor Properties of Nafion-Free, Vertically Aligned Pt Nanowire Array Electrodes.

Authors:  Zhiyang Li; Calvin Leung; Fan Gao; Zhiyong Gu
Journal:  Sensors (Basel)       Date:  2015-09-04       Impact factor: 3.576

8.  High sensitive and selective sensing of hydrogen peroxide released from pheochromocytoma cells based on Pt-Au bimetallic nanoparticles electrodeposited on reduced graphene sheets.

Authors:  Guangxia Yu; Weixiang Wu; Xiaoqi Pan; Qiang Zhao; Xiaoyun Wei; Qing Lu
Journal:  Sensors (Basel)       Date:  2015-01-26       Impact factor: 3.576

9.  Real-time monitoring of cellular oxidative stress during aerosol sampling: a proof of concept study.

Authors:  Lynn E Secondo; Vitaliy Avrutin; Umit Ozgur; Erdem Topsakal; Nastassja A Lewinski
Journal:  Drug Chem Toxicol       Date:  2020-06-12       Impact factor: 3.356

10.  MnO nanoparticle@mesoporous carbon composites grown on conducting substrates featuring high-performance lithium-ion battery, supercapacitor and sensor.

Authors:  Tianyu Wang; Zheng Peng; Yuhang Wang; Jing Tang; Gengfeng Zheng
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.