Literature DB >> 19288156

A high-resolution, three-dimensional thin endoscope for fetal surgery.

E Kobayashi1, T Ando, H Yamashita, I Sakuma, T Fukuyo, K Ando, T Chiba.   

Abstract

BACKGROUND: Fetal surgery is receiving considerable attention. However, surgeons must have great skill to perform this surgery. For assisting with the operation, the three-dimensional (3D) endoscope is very useful because it allows the surgeon depth perception. However, the diameter of existing 3D endoscopes is approximately 10 mm. Therefore, the authors have developed a high-resolution, thin, 3D endoscope for use in fetal surgery.
METHODS: The authors' system uses two 1/10-in. micro charge-coupled device (CCD) cameras at the tip of the endoscope and achieves a diameter of 5.4 mm. The endoscope's angle of convergence is 2.6 masculine, which very closely approximates the angle of convergence for humans. Thus, the surgeon experiences little visual fatigue. The view angle is 87 masculine.
RESULTS: The authors compared image quality and depth perception between their system and conventional 3D and 2D endoscopes. Theoretical investigation of image quality allowed the surgeon to distinguish a line 0.2 to 0.25 mm wide. Furthermore, the depth perception with the thin 3D endoscope was almost the same as with an 11-mm normal 3D endoscope. In addition, with the 3D endoscope, a higher percentage of questions were answered correctly in the depth perception evaluation experiment in a water environment than with the 2D instrument.
CONCLUSION: According to these experiments, the thin 3D endoscope has a sufficiently high image quality and depth perception even in a water environment.

Entities:  

Mesh:

Year:  2009        PMID: 19288156     DOI: 10.1007/s00464-009-0413-7

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  6 in total

1.  A new concept of three-dimensional endoscope for endoscopic surgery.

Authors:  Y Muragaki; M Hashizume; D Hashimoto; H Iseki; K Takakura
Journal:  Surg Endosc       Date:  2003-11       Impact factor: 4.584

2.  Effect of binocular stereopsis on surgical manipulation performance and fatigue when using a stereoscopic endoscope.

Authors:  Yasushi Yamauchi; Kazuhiko Shinohara
Journal:  Stud Health Technol Inform       Date:  2005

3.  Comparative study of two-dimensional and three-dimensional vision systems for minimally invasive surgery.

Authors:  P van Bergen; W Kunert; J Bessell; G F Buess
Journal:  Surg Endosc       Date:  1998-07       Impact factor: 4.584

4.  Three-dimensional video imaging for endoscopic surgery.

Authors:  A F Durrani; G M Preminger
Journal:  Comput Biol Med       Date:  1995-03       Impact factor: 4.589

5.  Three-dimensional imaging in endoscopic surgery.

Authors:  W P Griffin
Journal:  Biomed Instrum Technol       Date:  1995 May-Jun

6.  Three-dimensional video-endoscopy: clinical use in gynaecological laparoscopy.

Authors:  R Wenzl; R Lehner; U Vry; N Pateisky; P Sevelda; P Husslein
Journal:  Lancet       Date:  1994-12-10       Impact factor: 79.321

  6 in total
  5 in total

1.  A beam-splitter-type 3-D endoscope for front view and front-diagonal view images.

Authors:  Hiroki Kamiuchi; Ken Masamune; Kenta Kuwana; Takeyoshi Dohi; Keri Kim; Hiromasa Yamashita; Toshio Chiba
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-03-23       Impact factor: 2.924

2.  3-D endoscope using a single CCD camera and pneumatic vibration mechanism.

Authors:  Hiroki Kamiuchi; Kenta Kuwana; Tsuneo Fukuyo; Hiromasa Yamashita; Toshio Chiba; Takeyoshi Dohi; Ken Masamune
Journal:  Surg Endosc       Date:  2012-12-12       Impact factor: 4.584

3.  A randomized prospective study comparing acquisition of laparoscopic skills in three-dimensional (3D) vs. two-dimensional (2D) laparoscopy.

Authors:  B Alaraimi; W El Bakbak; S Sarker; S Makkiyah; A Al-Marzouq; R Goriparthi; A Bouhelal; V Quan; B Patel
Journal:  World J Surg       Date:  2014-11       Impact factor: 3.352

4.  Multi-view vision system for laparoscopy surgery.

Authors:  Brahim Tamadazte; Anthony Agustinos; Philippe Cinquin; Gaelle Fiard; Sandrine Voros
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-05-14       Impact factor: 2.924

5.  Self-contained image mapping of placental vasculature in 3D ultrasound-guided fetoscopy.

Authors:  Liangjing Yang; Junchen Wang; Takehiro Ando; Akihiro Kubota; Hiromasa Yamashita; Ichiro Sakuma; Toshio Chiba; Etsuko Kobayashi
Journal:  Surg Endosc       Date:  2015-12-10       Impact factor: 4.584

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.