Literature DB >> 19286872

Frictional resistance in plastic preadjusted brackets ligated with low-friction and conventional elastomeric ligatures.

Hideki Ioi1, Yumi Yanase, Michiya Uehara, Atsushi Hara, Shunsuke Nakata, Akihiko Nakasima, Amy L Counts.   

Abstract

OBJECTIVE: To compare frictional resistance of the plastic preadjusted brackets ligated with the low-friction ligatures with those of the conventional elastomeric ligatures.
DESIGN: In vitro study.
SETTING: Department of Orthodontics, Faculty of Dentistry, Kyushu University, Fukuoka, Japan.
MATERIALS AND METHODS: The testing model consisted of four 0.022-inch plastic preadjusted brackets for the first premolar, the canine, the lateral incisor, and the central incisor. A superelastic nickel-titanium 0.014-inch wire and a stainless steel 0.019 x 0.025-inch wire were used for this test. The brackets were either aligned or out of line by 0.5, 1.0, 1.5 and 2.0 mm for the 0.014-inch wire and aligned for the 0.019 x 0.025-inch wire. The frictional forces in plastic preadjusted brackets with low-friction ligatures and conventional elastomeric ligatures were measured at a pulling speed of 0.1 mm/second. Welch t-tests were used to compare the mean differences of each testing measurement between the low-friction and the conventional elastomeric ligatures.
RESULTS: In both use of the superelastic nickel-titanium 0.014-inch wire and the stainless steel 0.019 x 0.025-inch wire, the brackets with the low-friction ligatures showed significantly lower frictional forces than those of the conventional elastomeric ligatures in both aligned and all misaligned brackets (P < 0.0001).
CONCLUSION: The study found the significantly lower frictional forces for the low-friction ligatures than those of the conventional elastomeric ligatures.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19286872     DOI: 10.1179/14653120722887

Source DB:  PubMed          Journal:  J Orthod        ISSN: 1465-3125


  3 in total

1.  Comparison of friction produced by two types of orthodontic bracket protectors.

Authors:  Steyner de Lima Mendonça; Otávio José Praxedes Neto; Patricia Teixeira de Oliveira; Patricia Bittencourt Dutra dos Santos; Fábio Henrique de Sá Leitão Pinheiro
Journal:  Dental Press J Orthod       Date:  2014 Jan-Feb

2.  Useful design of custom-made mouthguard for athletes undergoing orthodontic treatment with brackets and wires.

Authors:  Ruman Uddin Chowdhury; Hiroshi Churei; Gen Tanabe; Yuriko Yoshida; Kairi Hayashi; Hidekazu Takahashi; Takahiro Wada; Motohiro Uo; Takahiro Mizobuchi; Nafees Uddin Chowdhury; Toshiaki Ueno
Journal:  J Dent Sci       Date:  2021-04-09       Impact factor: 2.080

Review 3.  Resistance to sliding in orthodontics: misconception or method error? A systematic review and a proposal of a test protocol.

Authors:  Fabio Savoldi; Aggeliki Papoutsi; Simona Dianiskova; Domenico Dalessandri; Stefano Bonetti; James K H Tsoi; Jukka P Matinlinna; Corrado Paganelli
Journal:  Korean J Orthod       Date:  2018-07-06       Impact factor: 1.372

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.