Literature DB >> 19285089

Measurement depth and volume in laser Doppler flowmetry.

Ingemar Fredriksson1, Marcus Larsson, Tomas Strömberg.   

Abstract

A new method for estimating the measurement depth and volume in laser Doppler flowmetry (LDF) is presented. The method is based on Monte Carlo simulations of light propagation in tissue. The contribution from each individual Doppler shift is calculated and thereby multiple Doppler shifts are handled correctly. Different LDF setups for both probe based (0.0, 0.25, 0.5, and 1.2 mm source-detector separation) and imaging systems (0.5 and 2.0 mm beam diameter) are considered, at the wavelengths 543 nm, 633 nm, and 780 nm. Non-linear speckle pattern effects are accounted for in the imaging system setups. The effects of tissue optical properties, blood concentration, and blood oxygen saturation are evaluated using both homogeneous tissue models and a layered skin model. The results show that the effect on the measurement depth of changing tissue properties is comparable to the effect of changing the system setup, e.g. source-detector separation and wavelength. Skin pigmentation was found to have a negligible effect on the measurement depth. Examples of measurement depths are (values are given for a probe based system with 0.25 mm source-detector separation and an imaging system with a 0.5 mm beam diameter, respectively, both operating at 780 nm): muscle - 0.55/0.79 mm; liver - 0.40/0.53 mm; gray matter - 0.48/0.68 mm; white matter - 0.20/0.20 mm; index finger pulp - 0.41/0.53 mm; forearm skin - 0.53/0.56 mm; heat provoked forearm skin - 0.66/0.67 mm.

Entities:  

Mesh:

Year:  2009        PMID: 19285089     DOI: 10.1016/j.mvr.2009.02.008

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  27 in total

Review 1.  Resting blood flow in the skin: does it exist, and what is the influence of temperature, aging, and diabetes?

Authors:  Jerrold Scott Petrofsky
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

2.  Serial assessment of laser Doppler flow during acute pain crises in sickle cell disease.

Authors:  Patricia Ann Shi; Deepa Manwani; Olugbenga Olowokure; Vijay Nandi
Journal:  Blood Cells Mol Dis       Date:  2014-05-21       Impact factor: 3.039

3.  Self-mixing microprobe for monitoring microvascular perfusion in rat brain.

Authors:  Edite Figueiras; Ricardo Oliveira; Cátia F Lourenço; Rita Campos; Anne Humeau-Heurtier; Rui M Barbosa; João Laranjinha; Luis F Requicha Ferreira; Frits F M de Mul
Journal:  Med Biol Eng Comput       Date:  2012-10-12       Impact factor: 2.602

4.  Optical-thermal light-tissue interactions during photoacoustic breast imaging.

Authors:  Taylor Gould; Quanzeng Wang; T Joshua Pfefer
Journal:  Biomed Opt Express       Date:  2014-02-24       Impact factor: 3.732

5.  Cocaine Decreases Spontaneous Neuronal Activity and Increases Low-Frequency Neuronal and Hemodynamic Cortical Oscillations.

Authors:  Wei Chen; Nora D Volkow; James Li; Yingtian Pan; Congwu Du
Journal:  Cereb Cortex       Date:  2019-04-01       Impact factor: 5.357

6.  Measuring niacin-associated skin toxicity (NASTy) stigmata along with symptoms to aid development of niacin mimetics.

Authors:  Richard L Dunbar; Harsh Goel; Sony Tuteja; Wen-Liang Song; Grace Nathanson; Zeeshan Babar; Dusanka Lalic; Joel M Gelfand; Daniel J Rader; Gary L Grove
Journal:  J Lipid Res       Date:  2017-01-23       Impact factor: 5.922

7.  Transcranial contrast-enhanced ultrasound in the rat brain reveals substantial hyperperfusion acutely post-stroke.

Authors:  Dino Premilovac; Sarah J Blackwood; Ciaran J Ramsay; Michelle A Keske; David W Howells; Brad A Sutherland
Journal:  J Cereb Blood Flow Metab       Date:  2020-02-17       Impact factor: 6.200

8.  Reduced arteriovenous shunting capacity after local heating and redistribution of baseline skin blood flow in type 2 diabetes assessed with velocity-resolved quantitative laser Doppler flowmetry.

Authors:  Ingemar Fredriksson; Marcus Larsson; Fredrik H Nyström; Toste Länne; Carl J Ostgren; Tomas Strömberg
Journal:  Diabetes       Date:  2010-04-14       Impact factor: 9.461

9.  Isoflurane anesthesia does not affect spinal cord neurovascular coupling: evidence from decerebrated rats.

Authors:  Thierry Paquette; Hugues Leblond; Mathieu Piché
Journal:  J Physiol Sci       Date:  2018-03-29       Impact factor: 2.781

10.  Perfusion Assessment in Critical Limb Ischemia: Principles for Understanding and the Development of Evidence and Evaluation of Devices: A Scientific Statement From the American Heart Association.

Authors:  Sanjay Misra; Mehdi H Shishehbor; Edwin A Takahashi; Herbert D Aronow; Luke P Brewster; Matthew C Bunte; Esther S H Kim; Jonathan R Lindner; Kathleen Rich
Journal:  Circulation       Date:  2019-08-12       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.