A revised conversion factor relating respirable dust concentrations measured by 10 mm Dorr-Oliver nylon cyclones operated at 1.7 and 2.0 L min(-1).

Steven J Page1, Jon C Volkwein.   

Abstract

Accurate measurement of workplace respirable dust concentration is an essential step in eliminating lung disease in any occupational setting. In the United States (U.S.) coal mining industry, this measurement process has relied upon a personal sampler that includes a 10 mm Dorr-Oliver (DO) nylon cyclone operated at a flow rate of 2.0 L min(-1) to collect a respirable dust sample. Dust concentrations measured with this sampler are multiplied by 1.38, which was empirically derived, to convert them to measurements approximating the United Kingdom British Medical Research Council (BMRC) definition of respirable dust upon which the health effects of coal mine dust are based. The International Organization for Standardization (ISO) subsequently refined the respirable dust definition and the U.S. National Institute for Occupational Safety and Health (NIOSH) 1995 Criteria for a Recommended Standard presented a conversion multiplier of 0.857 to apply to the 2.0 L min(-1) DO (in addition to the1.38 multiplier) to obtain equivalent ISO concentrations, as approximated by the 1.7 L min(-1) DO. However, the conversion multiplier 0.857 was derived indirectly from a limited size distribution data set rather than a direct comparison of the DO samplers. The present analysis focuses on providing a more accurate conversion multiplier derived from direct comparisons of the 2.0 L min(-1) (with 1.38 BMRC equivalency multiplier) and 1.7 L min(-1) DO cyclones. A weighted linear regression analysis of this database suggests that a more accurate estimate of the conversion multiplier is 0.815.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19280048     DOI: 10.1039/b817922k

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  3 in total

1.  An evaluation of sharp cut cyclones for sampling diesel particulate matter aerosol in the presence of respirable dust.

Authors:  Emanuele Cauda; Maura Sheehan; Robert Gussman; Lee Kenny; Jon Volkwein
Journal:  Ann Occup Hyg       Date:  2014-07-24

2.  Respirable size-selective sampler for end-of-shift quartz measurement: Development and performance.

Authors:  Taekhee Lee; Larry Lee; Emanuele Cauda; Jon Hummer; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2017-05       Impact factor: 2.155

3.  Evaluating the use of a field-based silica monitoring approach with dust from copper mines.

Authors:  Emanuele Cauda; Lauren Chubb; Rustin Reed; Robert Stepp
Journal:  J Occup Environ Hyg       Date:  2018-10       Impact factor: 2.155