Literature DB >> 19279314

Lower volumes of tear menisci in contact lens wearers with dry eye symptoms.

Qi Chen1, Jianhua Wang, Meixiao Shen, Chunyan Cai, Jianhua Li, Lele Cui, Jia Qu, Fan Lu.   

Abstract

PURPOSE: To investigate tear meniscus volumes during short-term lens wear by soft contact lens (SCL) wearers with dryness symptoms.
METHODS: Three groups of 20 subjects were recruited. Group 1 consisted of SCL wearers with self-reported dryness. Group 2 consisted of asymptomatic wearers. Group 3 was composed of asymptomatic non-lens wearers. Contact lenses were fitted on each eye, and both upper and lower tear menisci were imaged before lens insertion, immediately afterward, and 30 minutes later, using optical coherence tomography. Custom software was used to yield the tear meniscus area, and then the volumes were calculated based on eyelid length. Repeatability was tested 30 minutes after lens wear on two consecutive days.
RESULTS: There were no significant differences (P > 0.05) between the volumes measured at 30 minutes after lens insertion on 2 days. In addition, the repeatability between days was similar among the groups. The upper and lower meniscus volumes were significantly lower in group 1 than in either of the asymptomatic groups at baseline, immediately after insertion, and 30 minutes later (P < 0.05). The upper tear meniscus in group 3 was greater than in group 2 at all times (P < 0.05). The lower meniscus volume immediately after insertion was significantly higher in group 3, the inexperienced wearers, than in group 2 (P < 0.05); however, the volumes at baseline and 30 minutes later were similar to one another (P > 0.05).
CONCLUSIONS: Tear volumes in dry eye symptomatic wearers were lower than asymptomatic wearers at baseline and during lens wear, which may have contributed to the dryness.

Entities:  

Mesh:

Year:  2009        PMID: 19279314     DOI: 10.1167/iovs.08-2794

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  15 in total

Review 1.  The watery eye.

Authors:  Jianhua Wang; Meixiao Shen; Lele Cui; Michael R Wang
Journal:  Curr Allergy Asthma Rep       Date:  2011-06       Impact factor: 4.806

2.  Anterior segment optical coherence tomography: a diagnostic instrument for conjunctivochalasis.

Authors:  Koray Gumus; Charlene Hong Crockett; Stephen C Pflugfelder
Journal:  Am J Ophthalmol       Date:  2010-12       Impact factor: 5.258

3.  Lid Wiper Microvascular Responses as an Indicator of Contact Lens Discomfort.

Authors:  Zhihong Deng; Jianhua Wang; Hong Jiang; Zohra Fadli; Che Liu; Jia Tan; Jin Zhou
Journal:  Am J Ophthalmol       Date:  2016-08-16       Impact factor: 5.258

4.  Daytime variations of tear osmolarity and tear meniscus volume.

Authors:  Ming Li; Chixin Du; Dexi Zhu; Meixiao Shen; Lele Cui; Jianhua Wang
Journal:  Eye Contact Lens       Date:  2012-09       Impact factor: 2.018

5.  Automatic dynamic tear meniscus measurement in optical coherence tomography.

Authors:  Maciej M Bartuzel; Dorota H Szczesna-Iskander; D Robert Iskander
Journal:  Biomed Opt Express       Date:  2014-07-23       Impact factor: 3.732

6.  Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment.

Authors:  Jianhua Wang; Lele Cui; Meixiao Shen; Victor L Perez; Michael R Wang
Journal:  Clin Ophthalmol       Date:  2012-06-20

7.  Effect of fluorometholone/tetrahydrozoline fixed combination on conjunctival autograft morphology after primary pterygium excision.

Authors:  Engin Bilge Ozgurhan; Necip Kara; Ercument Bozkurt; Baran Gencer; Alper Agca; Zeynep Alkin; Ahmet Demirok
Journal:  Biomed Res Int       Date:  2013-06-20       Impact factor: 3.411

Review 8.  A Review of Imaging Biomarkers of the Ocular Surface.

Authors:  William W Binotti; Betul Bayraktutar; M Cuneyt Ozmen; Stephanie M Cox; Pedram Hamrah
Journal:  Eye Contact Lens       Date:  2020-03       Impact factor: 3.152

9.  Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens.

Authors:  Nery García-Porta; Laura Rico-del-Viejo; Helena Ferreira-Neves; Sofia C Peixoto-de-Matos; Antonio Queirós; José M González-Méijome
Journal:  Biomed Res Int       Date:  2015-03-31       Impact factor: 3.411

10.  Comparison of conjunctival graft thickness after primary and recurrent pterygium surgery: anterior segment optical coherence tomography study.

Authors:  Engin Bilge Ozgurhan; Necip Kara; Ercument Bozkurt; Baran Gencer; Kemal Yuksel; Ahmet Demirok
Journal:  Indian J Ophthalmol       Date:  2014-06       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.