Literature DB >> 19278327

Biomechanical rigidity of cadaveric cervical spine with posterior versus combined posterior and anterior instrumentation.

Nader S Dahdaleh1, Satoshi Nakamura, James C Torner, Tae-Hong Lim, Patrick W Hitchon.   

Abstract

OBJECT: In patients with cervical stenosis with myelopathy, posterior instrumentation following cervical laminectomy has been shown to reduce the incidence of postoperative instability and kyphosis. However, the indications for posterior plus anterior instrumentation are not always obvious, and using both posterior and anterior instrumentation routinely is unnecessary and excessive. This study examines the rigidity of the intact isolated cadaveric cervical spine, after C4-6 laminectomy, with posterior lateral mass instrumentation, and following posterior plus anterior instrumentation.
METHODS: Ten fresh-frozen human cadaveric cervical spines from C-1 to T-2 were potted in the neutral position, and retroreflective markers were placed on C-3 and C-7. Specimens were mounted on a biomechanical testing frame, and angular rotations of C-3 relative to C-7 were measured. Pure moments of 0, 0.3, 0.6, 0.9, and 1.2 Nm were applied at C-2 in all 3 planes. Each specimen was load tested as follows: 1) in the intact state; 2) after C4-6 laminectomy; 3) with C3-7 lateral mass instrumentation; and 4) with C3-7 posterior plus anterior instrumentation.
RESULTS: Laminectomy was not associated with a significant increase in motion compared with the intact state with any load or in any direction. Instrumentation was associated with reduction in motion in all directions, and there was no significant difference in posterior versus combined posterior and anterior instrumentation.
CONCLUSIONS: Rigidity imparted to the cervical spine by a 5-level posterior lateral mass fixation is not augmented by anterior instrumentation.

Entities:  

Mesh:

Year:  2009        PMID: 19278327     DOI: 10.3171/2008.11.SPI08416

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  4 in total

1.  The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping.

Authors:  Heiko Koller; Rene Schmidt; Michael Mayer; Wolfgang Hitzl; Juliane Zenner; Stefan Midderhoff; Stefan Middendorf; Nicolaus Graf; Nicolaus Gräf; H Resch; Hans-Joachim Wilke; Hans-Joachim Willke
Journal:  Eur Spine J       Date:  2010-06-30       Impact factor: 3.134

2.  Anterior transpedicular screws in conjunction with plate fixation and fusion for the treatment of subaxial cervical spine diseases.

Authors:  Jie Li; Liujun Zhao; Wangmi Liu; Weihu Ma; Rongming Xu; Wei-Yu Jiang; Yongjie Gu; Liangjie Lu; Liang Yu; Feng Qi
Journal:  Eur Spine J       Date:  2015-02-20       Impact factor: 3.134

3.  Single-stage Anterior and Posterior Fusion Surgery for Correction of Cervical Kyphotic Deformity Using Intervertebral Cages and Cervical Lateral Mass Screws: Postoperative Changes in Total Spine Sagittal Alignment in Three Cases with a Minimum Follow-up of Five Years.

Authors:  Satoshi Ogihara; Junichi Kunogi
Journal:  Neurol Med Chir (Tokyo)       Date:  2015-06-29       Impact factor: 1.742

4.  Posterior decompression and internal fixation in treatment of hypertrophy of posterior longitudinal ligament at C1-2 level accompanied with lower cervical spinal stenosis: A case report.

Authors:  Huan Liu; Tao Wang; Hui Wang; Wen-Yuan Ding
Journal:  Medicine (Baltimore)       Date:  2016-12       Impact factor: 1.889

  4 in total