Literature DB >> 19277959

Development and validation of a highly sensitive and robust LC-ESI-MS/MS method for simultaneous quantitation of simvastatin acid, amlodipine and valsartan in human plasma: application to a clinical pharmacokinetic study.

Addepalli V Ramani1, Pinaki Sengupta, Ramesh Mullangi.   

Abstract

A high-throughput, simple, highly sensitive and specific LC-MS/MS method has been developed for simultaneous estimation of simvastatin acid (SA), amlodipine (AD) and valsartan (VS) with 500 microL of human plasma using deuterated simvastatin acid as an internal standard (IS). The API-4000 LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using electrospray ionization. The assay procedure involved precipitation of SA, AD, VS and IS from plasma with acetonitrile. The total run time was 2.8 min and the elution of SA, AD, VS and IS occurred at 1.81, 1.12, 1.14 and 1.81 min, respectively; this was achieved with a mobile phase consisting of 0.02 M ammonium formate (pH 4.5):acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on an X-Terra C18 column. A linear response function was established for the range of concentrations 0.5-50 ng/mL (r > 0.994) for VS and 0.2-50 ng/mL (r > 0.996) for SA and AD. The method validation parameters for all three analytes met the acceptance as per FDA guidelines. This novel method has been applied to human pharmacokinetic study.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19277959     DOI: 10.1002/bmc.1161

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  8 in total

Review 1.  Innovations in asthma therapy: is there a role for inhaled statins?

Authors:  Amir A Zeki; Mona Elbadawi-Sidhu
Journal:  Expert Rev Respir Med       Date:  2018-05-03       Impact factor: 3.772

2.  Development and Validation of a LC-MS/MS Method for the Simultaneous Estimation of Amlodipine and Valsartan in Human Plasma: Application to a Bioequivalence Study.

Authors:  Hemanth Jangala; Poonam Vats; Arshad Hussain Khuroo; Tausif Monif
Journal:  Sci Pharm       Date:  2014-03-26

3.  Application of an LC-MS/MS method for the analysis of amlodipine, valsartan and hydrochlorothiazide in polypill for a bioequivalence study.

Authors:  Jaivik V Shah; Jignesh M Parekh; Priyanka A Shah; Priya V Shah; Mallika Sanyal; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2017-06-04

4.  Simultaneous determination of telmisartan and amlodipine in human plasma by LC-MS/MS and its application in a human pharmacokinetic study.

Authors:  Vasu Babu Ravi; Jaswanth Kumar Inamadugu; Nageswara Rao Pilli; Vudagandla Sreenivasulu; Venkateswarlu Ponneri
Journal:  J Pharm Anal       Date:  2012-04-04

5.  Simultaneous determination of amlodipine, valsartan and hydrochlorothiazide by LC-ESI-MS/MS and its application to pharmacokinetics in rats.

Authors:  Shankar Ganesh Gadepalli; Pragney Deme; Madhusudana Kuncha; Ramakrishna Sistla
Journal:  J Pharm Anal       Date:  2013-12-19

6.  Validated LC-MS/MS method for simultaneous determination of SIM and its acid form in human plasma and cell lysate: Pharmacokinetic application.

Authors:  Tamer A Ahmed; Jamie Horn; John Hayslip; Markos Leggas
Journal:  J Pharm Anal       Date:  2012-08-07

7.  Development of an HPLC-UV Method for the Analysis of Drugs Used for Combined Hypertension Therapy in Pharmaceutical Preparations and Human Plasma.

Authors:  Serife Evrim Kepekci Tekkeli
Journal:  J Anal Methods Chem       Date:  2013-03-24       Impact factor: 2.193

8.  Estimation of Amlodipine Besylate, Valsartan and Hydrochlorothiazide in Bulk Mixture and Tablet by UV Spectrophotometry.

Authors:  Varsha R Galande; K G Baheti; S Indraksha; M H Dehghan
Journal:  Indian J Pharm Sci       Date:  2012-01       Impact factor: 0.975

  8 in total