Literature DB >> 19273001

Convergence and parameter choice for Monte-Carlo simulations of diffusion MRI.

Matt G Hall1, Daniel C Alexander.   

Abstract

This paper describes a general and flexible Monte- Carlo simulation framework for diffusing spins that generates realistic synthetic data for diffusion magnetic resonance imaging. Similar systems in the literature consider only simple substrates and their authors do not consider convergence and parameter optimization. We show how to run Monte-Carlo simulations within complex irregular substrates. We compare the results of the Monte-Carlo simulation to an analytical model of restricted diffusion to assess precision and accuracy of the generated results. We obtain an optimal combination of spins and updates for a given run time by trading off number of updates in favor of number of spins such that precision and accuracy of sythesized data are both optimized. Further experiments demonstrate the system using a tissue environment that current analytic models cannot capture. This tissue model incorporates swelling, abutting, and deformation. Swelling-induced restriction in the extracellular space due to the effects of abutting cylinders leads to large departures from the predictions of the analytical model, which does not capture these effects. This swelling-induced restriction may be an important mechanism in explaining the changes in apparent diffusion constant observed in the aftermath of acute ischemic stroke.

Entities:  

Mesh:

Year:  2009        PMID: 19273001     DOI: 10.1109/TMI.2009.2015756

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  58 in total

1.  Neurite beading is sufficient to decrease the apparent diffusion coefficient after ischemic stroke.

Authors:  Matthew D Budde; Joseph A Frank
Journal:  Proc Natl Acad Sci U S A       Date:  2010-07-26       Impact factor: 11.205

2.  Assessing the validity of the approximation of diffusion-weighted-MRI signals from crossing fascicles by sums of signals from single fascicles.

Authors:  Gaëtan Rensonnet; Benoît Scherrer; Simon K Warfield; Benoît Macq; Maxime Taquet
Journal:  Magn Reson Med       Date:  2017-07-16       Impact factor: 4.668

3.  Diffusion-time dependence of diffusional kurtosis in the mouse brain.

Authors:  Manisha Aggarwal; Matthew D Smith; Peter A Calabresi
Journal:  Magn Reson Med       Date:  2020-02-05       Impact factor: 4.668

4.  Assessing the accuracy of using oscillating gradient spin echo sequences with AxCaliber to infer micron-sized axon diameters.

Authors:  Morgan Mercredi; Trevor J Vincent; Christopher P Bidinosti; Melanie Martin
Journal:  MAGMA       Date:  2016-07-13       Impact factor: 2.310

5.  Simulations on the influence of myelin water in diffusion-weighted imaging.

Authors:  K D Harkins; M D Does
Journal:  Phys Med Biol       Date:  2016-06-08       Impact factor: 3.609

6.  Automatic Segmentation of the Dorsal Claustrum in Humans Using in vivo High-Resolution MRI.

Authors:  Shai Berman; Roey Schurr; Gal Atlan; Ami Citri; Aviv A Mezer
Journal:  Cereb Cortex Commun       Date:  2020-09-01

7.  Design and validation of diffusion MRI models of white matter.

Authors:  Ileana O Jelescu; Matthew D Budde
Journal:  Front Phys       Date:  2017-11-28

8.  Towards microstructure fingerprinting: Estimation of tissue properties from a dictionary of Monte Carlo diffusion MRI simulations.

Authors:  Gaëtan Rensonnet; Benoît Scherrer; Gabriel Girard; Aleksandar Jankovski; Simon K Warfield; Benoît Macq; Jean-Philippe Thiran; Maxime Taquet
Journal:  Neuroimage       Date:  2018-09-30       Impact factor: 6.556

Review 9.  The role of tissue microstructure and water exchange in biophysical modelling of diffusion in white matter.

Authors:  Markus Nilsson; Danielle van Westen; Freddy Ståhlberg; Pia C Sundgren; Jimmy Lätt
Journal:  MAGMA       Date:  2013-02-27       Impact factor: 2.310

10.  Simulation of changes in diffusion related to different pathologies at cellular level after traumatic brain injury.

Authors:  Mu Lin; Hongjian He; Giovanni Schifitto; Jianhui Zhong
Journal:  Magn Reson Med       Date:  2015-08-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.