Literature DB >> 19272985

Pulse wave imaging of normal and aneurysmal abdominal aortas in vivo.

Jianwen Luo1, Kana Fujikura, Leslie S Tyrie, M David Tilson, Elisa E Konofagou.   

Abstract

The abdominal aortic aneurysm (AAA) is a common vascular disease. The current clinical criterion for treating AAAs is an increased diameter above a critical value. However, the maximum diameter does not correlate well with aortic rupture, the main cause of death from AAA disease. AAA disease leads to changes in the aortic wall mechanical properties. The pulse-wave velocity (PWV) may indicate such a change. Because of limitations in temporal and spatial resolution, the widely used foot-to-foot method measures the global, instead of regional, PWV between two points at a certain distance in the circulation. However, mechanical properties are nonuniform along the normal and pathological (e.g., the AAA and atherosclerosis) arteries; thus, such changes are typically regional. Pulse-wave imaging (PWI) has been developed by our group to map the pulse-wave propagation along the abdominal aorta in mice in vivo. By using a retrospective electrocardiogram (ECG) gating technique, the radio-frequency (RF) signals over one cardiac cycle were obtained in murine aortas at the extremely high frame rate of 8 kHz and with a field-of-view (FOV) of 12 x 12 mm(2). The velocities of the aortic wall were estimated using an RF-based speckle tracking method. An Angiotensin II (AngII) infusion-based AAA model was used to simulate the human AAA case. Sequences of wall velocity images can noninvasively and quantitatively map the propagation of the pulse wave along the aortic wall. In the normal and sham aortas, the propagation of the pulse wave was relatively uniform along the wall, while in the AngII-treated aortas, the propagation was shown to be nonuniform. There was no significant difference ( p > 0.05) in the PWV between sham (4.67 +/- 1.15 m/s, n=5) and AngII-treated (4.34 +/- 1.48 m/s, n=17) aortas. The correlation coefficient of the linear regression was significantly higher ( p < 0.005) in the sham aortas (0.89 +/- 0.03, n=5 ) than in the AngII-treated ones (0.61 +/- 0.15, n=17). The wall velocities induced by the pulse wave were lower and the pulse wave moved nonuniformly along the AngII-treated aorta ( p < 0.005), with the lowest velocities at the aneurysmal regions. The discrepancy in the regional wall velocity and the nonuniform pulse-wave propagation along the AngII-treated aorta indicated the inhomogeneities in the aortic wall properties, and the reduced wall velocities indicated stiffening of the aneurysmal wall. This novel technique may thus constitute an early detection tool of vascular degeneration as well as serve as a suitable predictor of AAA rupture, complementary to the current clinical screening practice.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19272985     DOI: 10.1109/TMI.2008.928179

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  41 in total

1.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

Review 2.  Lessons from Animal Models of Arterial Aneurysm.

Authors:  S David Gertz; Yoav Mintz; Ronen Beeri; Chen Rubinstein; Dan Gilon; Leah Gavish; Yacov Berlatzky; Liat Appelbaum; Lilach Gavish
Journal:  Aorta (Stamford)       Date:  2013-10-01

3.  Pulse wave imaging for noninvasive and quantitative measurement of arterial stiffness in vivo.

Authors:  Jonathan Vappou; Jianwen Luo; Elisa E Konofagou
Journal:  Am J Hypertens       Date:  2010-01-21       Impact factor: 2.689

4.  Assessing the Stability of Aortic Aneurysms with Pulse Wave Imaging.

Authors:  Sacha D Nandlall; Elisa E Konofagou
Journal:  Radiology       Date:  2016-06-08       Impact factor: 11.105

5.  A fast normalized cross-correlation calculation method for motion estimation.

Authors:  Jianwen Luo; Elisa Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-06       Impact factor: 2.725

6.  Pulse wave imaging using coherent compounding in a phantom and in vivo.

Authors:  Iason Zacharias Apostolakis; Matthew D J McGarry; Ethan A Bunting; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2016-12-21       Impact factor: 3.609

7.  Detecting Regional Stiffness Changes in Aortic Aneurysmal Geometries Using Pressure-Normalized Strain.

Authors:  Doran S Mix; Ling Yang; Camille C Johnson; Nathan Couper; Ben Zarras; Isaac Arabadjis; Lauren E Trakimas; Michael C Stoner; Steven W Day; Michael S Richards
Journal:  Ultrasound Med Biol       Date:  2017-07-17       Impact factor: 2.998

8.  Detection of Aortic Wall Inclusion Using Regional Pulse Wave Propagation and Velocity In Silico.

Authors:  Danial Shahmirzadi; Elisa E Konofagou
Journal:  Artery Res       Date:  2012-09       Impact factor: 0.597

9.  Pulse wave imaging in normal, hypertensive and aneurysmal human aortas in vivo: a feasibility study.

Authors:  Ronny X Li; Jianwen Luo; Sandhya K Balaram; Farooq A Chaudhry; Danial Shahmirzadi; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2013-06-14       Impact factor: 3.609

10.  Evaluation of aortic stiffness (aortic pulse-wave velocity) before and after elective abdominal aortic aneurysm repair procedures: a pilot study.

Authors:  Kosmas I Paraskevas; Nikolaos Bessias; Chrysovalantis Psathas; Konstantinos Akridas; Theodoros Dragios; Georgios Nikitas; Vassilios Andrikopoulos; Dimitri P Mikhailidis; Zenon S Kyriakides
Journal:  Open Cardiovasc Med J       Date:  2009-12-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.