Real-time management of faulty electrodes in electrical impedance tomography.

Alzbeta E Hartinger1, Robert Guardo, Andy Adler, Hervé Gagnon.   

Abstract

Completely or partially disconnected electrodes are a fairly common occurrence in many electrical impedance tomography (EIT) clinical applications. Several factors can contribute to electrode disconnection: patient movement, perspiration, manipulations by clinical staff, and defective electrode leads or electronics. By corrupting several measurements, faulty electrodes introduce significant image artifacts. In order to properly manage faulty electrodes, it is necessary to: 1) account for invalid data in image reconstruction algorithms and 2) automatically detect faulty electrodes. This paper presents a two-part approach for real-time management of faulty electrodes based on the principle of voltage-current reciprocity. The first part allows accounting for faulty electrodes in EIT image reconstruction without a priori knowledge of which electrodes are at fault. The method properly weights each measurement according to its compliance with the principle of voltage-current reciprocity. Results show that the algorithm is able to automatically determine the valid portion of the data and use it to calculate high-quality images. The second part of the approach allows automatic real-time detection of at least one faulty electrode with 100% sensitivity and two faulty electrodes with 80% sensitivity enabling the clinical staff to fix the problem as soon as possible to minimize data loss.

Entities:  

Mesh:

Year:  2008        PMID: 19272943     DOI: 10.1109/TBME.2008.2003103

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  Functional validation and comparison framework for EIT lung imaging.

Authors:  Bartłomiej Grychtol; Gunnar Elke; Patrick Meybohm; Norbert Weiler; Inéz Frerichs; Andy Adler
Journal:  PLoS One       Date:  2014-08-11       Impact factor: 3.240

2.  Analysis and compensation for errors in electrical impedance tomography images and ventilation-related measures due to serial data collection.

Authors:  Rebecca J Yerworth; Inéz Frerichs; Richard Bayford
Journal:  J Clin Monit Comput       Date:  2016-08-17       Impact factor: 2.502

3.  Fast detection and data compensation for electrodes disconnection in long-term monitoring of dynamic brain electrical impedance tomography.

Authors:  Ge Zhang; Meng Dai; Lin Yang; Weichen Li; Haoting Li; Canhua Xu; Xuetao Shi; Xiuzhen Dong; Feng Fu
Journal:  Biomed Eng Online       Date:  2017-01-07       Impact factor: 2.819

4.  An on-line processing strategy for head movement interferences removal of dynamic brain electrical impedance tomography based on wavelet decomposition.

Authors:  Ge Zhang; Weichen Li; Hang Ma; Xuechao Liu; Meng Dai; Canhua Xu; Haoting Li; Xiuzhen Dong; Xingwang Sun; Feng Fu
Journal:  Biomed Eng Online       Date:  2019-05-09       Impact factor: 2.819

Review 5.  Robust imaging using electrical impedance tomography: review of current tools.

Authors:  Benoit Brazey; Yassine Haddab; Nabil Zemiti
Journal:  Proc Math Phys Eng Sci       Date:  2022-02-02       Impact factor: 2.704

6.  Structural-functional lung imaging using a combined CT-EIT and a Discrete Cosine Transformation reconstruction method.

Authors:  Benjamin Schullcke; Bo Gong; Sabine Krueger-Ziolek; Manuchehr Soleimani; Ullrich Mueller-Lisse; Knut Moeller
Journal:  Sci Rep       Date:  2016-05-16       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.