Literature DB >> 19269495

A comparison of three analytical techniques for the measurement of steroidal estrogens in environmental water samples.

D P Grover1, Z L Zhang, J W Readman, J L Zhou.   

Abstract

Research into the analysis and monitoring of steroidal estrogens has grown significantly over the last decade, resulting in the emergence of a range of applicable techniques. In this study, three popular techniques, gas chromatography-mass spectrometry (GC-MS), gas chromatography-tandem mass spectrometry (GC-MS-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) for the analysis of three highly potent steroidal estrogens in the aquatic environment have been compared. It has been observed that overall, the three techniques appear comparable in generating similar estrogen concentrations for river and effluent samples. Of the three techniques, the GC-MS technique is the simplest to operate, but fails to detect the estrogens at the lower-end of environmentally relevant concentrations. The tandem MS techniques are more selective than MS, and therefore able to detect lower concentration levels of the three steroidal estrogens of interest. However, the LC-MS-MS technique is more susceptible to matrix interferences for the analysis of samples, resulting in a reduction of the signal-to-noise ratio and a subsequent reduction in reliability and stability compared to GC-MS-MS. With the GC-MS-MS technique offering increased selectivity, the lowest limits of detection, and no false positive identification, it is recommended to be the preferred analytical technique for routine analysis of estrogens in environmental water samples.

Mesh:

Substances:

Year:  2009        PMID: 19269495     DOI: 10.1016/j.talanta.2008.12.049

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  The importance of quality control in validating concentrations of contaminants of emerging concern in source and treated drinking water samples.

Authors:  Angela L Batt; Edward T Furlong; Heath E Mash; Susan T Glassmeyer; Dana W Kolpin
Journal:  Sci Total Environ       Date:  2017-02-01       Impact factor: 7.963

2.  Assessment of estrogenic contamination and biological effects in Lake Taihu.

Authors:  Guanghua Lu; Zhenhua Yan; Yonghua Wang; Wei Chen
Journal:  Ecotoxicology       Date:  2011-03-31       Impact factor: 2.823

3.  Separation of dansylated 17β-estradiol, 17α-estradiol, and estrone on a single HPLC column for simultaneous quantitation by LC-MS/MS.

Authors:  Szabolcs Szarka; Vien Nguyen; Laszlo Prokai; Katalin Prokai-Tatrai
Journal:  Anal Bioanal Chem       Date:  2013-02-01       Impact factor: 4.142

4.  A sensitive, robust method for determining natural and synthetic hormones in surface and wastewaters by continuous solid-phase extraction-gas chromatography-mass spectrometry.

Authors:  Safae Chafi; Evaristo Ballesteros
Journal:  Environ Sci Pollut Res Int       Date:  2022-03-15       Impact factor: 5.190

5.  Derivatization of estrogens enhances specificity and sensitivity of analysis of human plasma and serum by liquid chromatography tandem mass spectrometry.

Authors:  Abdullah M M Faqehi; Diego F Cobice; Gregorio Naredo; Tracy C S Mak; Rita Upreti; Fraser W Gibb; Geoffrey J Beckett; Brian R Walker; Natalie Z M Homer; Ruth Andrew
Journal:  Talanta       Date:  2015-12-29       Impact factor: 6.057

6.  Determination of Endocrine Disrupting Chemicals in Water and Wastewater Samples by Liquid Chromatography-Negative Ion Electrospray Ionization-Tandem Mass Spectrometry.

Authors:  Ghada Aborkhees; Renata Raina-Fulton; Ondiveerapan Thirunavokkarasu
Journal:  Molecules       Date:  2020-08-27       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.