Literature DB >> 19268892

Development and validation of a digital head posture measuring system.

Eric S Hald1, Richard W Hertle, Dongsheng Yang.   

Abstract

PURPOSE: To report the accuracy and repeatability of a new digital head posture measuring system.
DESIGN: Prospective study, clinical laboratory investigation.
METHODS: The digital head posture measuring system consists of a head-mounted motion tracker, a standard personal computer, and customized software to sample and display 3-dimensional (3D) head posture in real-time. Using a mechanical head posture measuring device as a reference, 3D head positions of an artificial head and 12 human subjects were recorded with the digital head posture device. Accuracy of the digital device outputs, relationship between digital outputs and actual head rotations, and repeatability of the tests were analyzed.
RESULTS: The digital head posture device showed consistent outcomes when compared to the mechanical one. The digital outputs of 3D rotations are very close to actual artificial head and human head rotations. The correlation coefficients of the linear relationship between the digital outputs and actual head movements were greater than 0.99. Repeatability tests for the artificial head and human subjects for all 3D rotations had 95% limits of agreement angles less than +/-6 degrees and +/-8 degrees, respectively.
CONCLUSIONS: The digital head posture device is an acceptable device with high accuracy, repeatability, and validity in measuring head posture in 3 dimensions.

Entities:  

Mesh:

Year:  2009        PMID: 19268892     DOI: 10.1016/j.ajo.2008.12.026

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  3 in total

1.  Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection technique.

Authors:  Urban Pavlovčič; Janez Diaci; Janez Možina; Matija Jezeršek
Journal:  Biomed Eng Online       Date:  2013-09-26       Impact factor: 2.819

2.  The Cambridge Face Tracker: Accurate, Low Cost Measurement of Head Posture Using Computer Vision and Face Recognition Software.

Authors:  Peter B M Thomas; Tadas Baltrušaitis; Peter Robinson; Anthony J Vivian
Journal:  Transl Vis Sci Technol       Date:  2016-09-30       Impact factor: 3.283

3.  Potential Usefulness of Tracking Head Movement via a Wearable Device for Equilibrium Function Testing at Home.

Authors:  Yoshiharu Yamanobe; Masato Fujioka; Masanao Ohashi; Hiroyuki Ozawa
Journal:  J Med Syst       Date:  2022-10-11       Impact factor: 4.920

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.