Literature DB >> 19267827

Endoscopy-guided occlusion of secundum atrial defect permits use of smaller, cosmetically superior thoracotomy.

Qiang Zhao1, Xiaoning Sun, Anqing Chen, Limin Xia, Zhe Wang M D.   

Abstract

BACKGROUND: Endoscopy has been introduced into cardiac surgery employing robotic systems. We have developed a new-minimally invasive approach that combines these two technologies for secundum atrial septal defect (ASD). The purpose of this study is to evaluate the efficacy of this approach, paying particular attention to its cosmetic effects.
METHODS: Between November 2004 and April 2006, 22 patients (aged 18 to 62) with ASDs (with sizes 10 to 39 mm) were treated with occlusion apparatus with endoscopy and robotic arm (AESOP 3000, Computer Motion Inc., Santa Barbara, CA, USA) assist.
RESULTS: All ASDs were successfully occluded with a mean device size of 26.8 mm (12 to 42 mm). Procedure time was ranged from 30 to 60 minutes. The ICU stay was less than 1 day and hospital stays was 3 to 7 days. No postoperative mortality was noted. During follow-up of 2 to 19 months, no major morbidities occurred.
CONCLUSIONS: Endoscopic ASD occlusion assisted with robotic is safe and effective with rapid recovery. The cosmetic effect is better results than conventional surgical repair.

Entities:  

Mesh:

Year:  2009        PMID: 19267827     DOI: 10.1111/j.1540-8191.2008.00804.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  3 in total

1.  Intraoperative device closure of atrial septal defects in the older population.

Authors:  Hui Zhang; Qiang Chen; Liang-Wan Chen; Hua Cao; Gui-Can Zhang; Dao-Zhong Chen
Journal:  J Cardiothorac Surg       Date:  2011-09-29       Impact factor: 1.637

2.  Safety and feasibility of intra-operative device closure of atrial septal defect with transthoracic minimal invasion.

Authors:  Qiang Chen; Hua Cao; Gui-Can Zhang; Liang-Wan Chen; Dao-Zhong Chen
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

3.  Comparative study of the transcatheter and transthoracic device closure treatments for atrial septal defect: A Chinese single-institution experience.

Authors:  Qiang Chen; Hua Cao; Zhao-Yang Chen; Gui-Can Zhang; Liang-Wan Chen; Fan Xu; Jia-Jun He
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.