Literature DB >> 19267529

Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. Laboratory investigation.

Satoshi Tateshima1, Kazuo Tanishita, Yasuhiro Hakata, Shin-ya Tanoue, Fernando Viñuela.   

Abstract

OBJECT: Development of a flexible self-expanding stent system and stent-assisted coiling technique facilitates endovascular treatment of wide-necked brain aneurysms. The hemodynamic effect of self-expandable stent placement across the neck of a brain aneurysm has not been well documented in patient-specific aneurysm models.
METHODS: Three patient-specific silicone aneurysm models based on clinical images were used in this study. Model 1 was constructed from a wide-necked internal carotid artery-ophthalmic artery aneurysm, and Models 2 and 3 were constructed from small wide-necked middle cerebral artery aneurysms. Neuroform stents were placed in the in vitro aneurysm models, and flow structures were compared before and after the stent placements. Flow velocity fields were acquired with particle imaging velocimetry.
RESULTS: In Model 1, a clockwise, single-vortex flow pattern was observed in the aneurysm dome before stenting was performed. There were multiple vortices, and a very small fast flow stream was newly formed in the aneurysm dome after stenting. The mean intraaneurysmal flow velocity was reduced by approximately 23-40%. In Model 2, there was a clockwise vortex flow in the aneurysm dome and another small counterclockwise vortex in the tip of the aneurysm dome before stenting. The small vortex area disappeared after stenting, and the mean flow velocity in the aneurysm dome was reduced by 43-64%. In Model 3, a large, counterclockwise, single vortex was seen in the aneurysm dome before stenting. Multiple small vortices appeared in the aneurysm dome after stenting, and the mean flow velocity became slower by 22-51%.
CONCLUSIONS: The flexible self-expandable stents significantly altered flow velocity and also flow structure in these aneurysms. Overall flow alterations by the stent appeared favorable for the long-term durability of aneurysm embolization. The possibility that the placement of a low-profile self-expandable stent might induce unfavorable flow patterns such as a fast flow stream in the aneurysm dome cannot be excluded.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19267529     DOI: 10.3171/2009.2.JNS081324

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  21 in total

1.  X-configured stent-assisted coiling in the endovascular treatment of complex anterior communicating artery aneurysms: a novel reconstructive technique.

Authors:  I Saatci; S Geyik; K Yavuz; S Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-01       Impact factor: 3.825

2.  Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients.

Authors:  Jacques Sedat; Yves Chau; Jean Gaudart; Marina Sachet; Stephanie Beuil; Michel Lonjon
Journal:  Neuroradiology       Date:  2017-12-23       Impact factor: 2.804

3.  Dual stenting using low-profile LEO baby stents for the endovascular management of challenging intracranial aneurysms.

Authors:  I Akmangit; K Aydin; S Sencer; O M Topcuoglu; E D Topcuoglu; E Daglioglu; M Barburoglu; A Arat
Journal:  AJNR Am J Neuroradiol       Date:  2014-09-18       Impact factor: 3.825

4.  Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?

Authors:  Jeongjun Lee; Young Dae Cho; Dong Hyun Yoo; Hyun-Seung Kang; Won-Sang Cho; Jeong Eun Kim; Jusun Moon; Moon Hee Han
Journal:  Neuroradiology       Date:  2018-04-20       Impact factor: 2.804

5.  Endovascular treatment of wide-neck intracranial bifurcation aneurysms with 'Y'-configuration, double Neuroform® stents-assisted coiling technique: Experience in a single center.

Authors:  C Castaño; M Terceño; S Remollo; M R García-Sort; C Domínguez
Journal:  Interv Neuroradiol       Date:  2017-06-06       Impact factor: 1.610

6.  Double stent-assisted coil embolization treatment for bifurcation aneurysms: immediate treatment results and long-term angiographic outcome.

Authors:  K Yavuz; S Geyik; S Cekirge; I Saatci
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-28       Impact factor: 3.825

Review 7.  Silicone models as basic training and research aid in endovascular neurointervention--a single-center experience and review of the literature.

Authors:  Srinivasan Paramasivam; Gerasimos Baltsavias; Evlampia Psatha; Georgios Matis; Anton Valavanis
Journal:  Neurosurg Rev       Date:  2014-01-25       Impact factor: 3.042

8.  The effect of aneurysm geometry on the intra-aneurysmal flow condition.

Authors:  Satoshi Tateshima; Aichi Chien; James Sayre; Juan Cebral; Fernando Viñuela
Journal:  Neuroradiology       Date:  2010-04-07       Impact factor: 2.804

9.  Coil embolization of anterior circulation aneurysms supported by the Solitaire AB Neurovascular Remodeling Device.

Authors:  Joachim Klisch; Christin Clajus; Vojtech Sychra; Cornelia Eger; Christoph Strasilla; Steffen Rosahl; Rüdiger Gerlach; Ingrid Bär; Heinrich Hoch; Uta Herbon; Ljubisa Borota; Per Jonasson; Thomas Liebig
Journal:  Neuroradiology       Date:  2009-07-31       Impact factor: 2.804

Review 10.  The safety and efficacy of stenting in the treatment of complex posterior cerebral artery aneurysms: a seven-case report and literature review.

Authors:  Q Huang; J Liu; R Zhao; B Hong; Y Xu; W Zhao; P Yang; W Li
Journal:  Clin Neuroradiol       Date:  2013-06-13       Impact factor: 3.649

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.