Literature DB >> 19267241

Single-molecule immunosorbent assay as a tool for human immunodeficiency virus-1 antigen detection.

Jiangwei Li1, Wenjun Xie, Ning Fang, Edward S Yeung.   

Abstract

Ultrasensitive detection and quantification of viral antigen with a novel single-molecule immunosorbent assay (SMISA) was achieved. Antigen from human immunodeficiency virus type 1 (HIV-1), the major etiological agent of acquired immune deficiency syndrome, served as the screening target in this study. The target molecule was sandwiched between a polyclonal capture antibody and a monoclonal detector antibody. The capture antibody was covalently immobilized on (3-glycidoxypropyl) trimethoxy silane-modified glass slides. The detector antibody was conjugated with fluorescent Alexa Fluor 532 labeled secondary antibody prior to being used as a probe for the antigen. Imaging was performed with a total internal reflection fluorescence single-molecule detection system. This technique is demonstrated for detecting HIV-1 p24 antigen down to 0.1 pg/mL with a dynamic range of over four orders of magnitude. A Langmuir isotherm fits the molecule count dependence on the target concentration. The target antigen was further tested in 20% human serum, and the results showed that neither sensitivity nor dynamic range was affected by the biological matrix. SMISA is therefore a promising approach for the early diagnosis of viral induced diseases.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19267241     DOI: 10.1007/s00216-009-2712-1

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

1.  Characterization of immune responses to capsid protein p24 of human immunodeficiency virus type 1 and implications for detection.

Authors:  Shixing Tang; Jiangqin Zhao; Aifeng Wang; Ragupathy Viswanath; Harri Harma; Richard F Little; Robert Yarchoan; Susan L Stramer; Phillipe N Nyambi; Sherwin Lee; Owen Wood; Eric Y Wong; Xue Wang; Indira K Hewlett
Journal:  Clin Vaccine Immunol       Date:  2010-06-09

2.  Increased Sensitivity of HIV-1 p24 ELISA Using a Photochemical Signal Amplification System.

Authors:  Simon Bystryak; Rasa Santockyte
Journal:  J Acquir Immune Defic Syndr       Date:  2015-10-01       Impact factor: 3.731

3.  Detection of HIV-1 p24 at Attomole Level by Ultrasensitive ELISA with Thio-NAD Cycling.

Authors:  Akira Nakatsuma; Mugiho Kaneda; Hiromi Kodama; Mika Morikawa; Satoshi Watabe; Kazunari Nakaishi; Masakane Yamashita; Teruki Yoshimura; Toshiaki Miura; Masaki Ninomiya; Etsuro Ito
Journal:  PLoS One       Date:  2015-06-22       Impact factor: 3.240

4.  Femtogram Level Sensitivity achieved by Surface Engineered Silica Nanoparticles in the Early Detection of HIV Infection.

Authors:  L A Avinash Chunduri; Aditya Kurdekar; Mohan Kumar Haleyurgirisetty; Eswarappa Pradeep Bulagonda; Venkataramaniah Kamisetti; Indira K Hewlett
Journal:  Sci Rep       Date:  2017-08-02       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.