Literature DB >> 19266826

Is I-gel a new revolution among supraglottic airway devices?--a comparative evaluation.

Parul Jindal1, Aslam Rizvi, J P Sharma.   

Abstract

In an attempt to reduce the pressor responses subsequent to laryngoscopy and intubation in normotensive anesthetized paralysed patients, the hemodynamic effects of three supraglottic devices were compared: I-gel, SLIPA, and LMA, The I-gel produced the least hemodynamic changes.

Entities:  

Mesh:

Year:  2009        PMID: 19266826

Source DB:  PubMed          Journal:  Middle East J Anaesthesiol        ISSN: 0544-0440


  14 in total

1.  Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia.

Authors:  Jong Bum Choi; Hyun Jeong Kwak; Kyung Cheon Lee; Se Ryeon Lee; Sook Young Lee; Jong Yeop Kim
Journal:  J Anesth       Date:  2016-01-13       Impact factor: 2.078

2.  i-gel™ in Ambulatory Surgery: A Comparison with LMA-ProSeal™ in Paralyzed Anaesthetized Patients.

Authors:  Anjan Das; Saikat Majumdar; Anindya Mukherjee; Tapobrata Mitra; Ratul Kundu; Bimal Kumar Hajra; Dipankar Mukherjee; Bibhukalyani Das
Journal:  J Clin Diagn Res       Date:  2014-03-15

3.  Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube.

Authors:  Hosam M Atef; Salah Abd Fattah; Mohammed Emad Abd Gaffer; Ahamed Abd Al Rahman
Journal:  Indian J Anaesth       Date:  2013-03

4.  Comparative study between I-gel, a new supraglottic airway device, and classical laryngeal mask airway in anesthetized spontaneously ventilated patients.

Authors:  Amr M Helmy; Hossam M Atef; Ezzat M El-Taher; Ahmed Mosaad Henidak
Journal:  Saudi J Anaesth       Date:  2010-09

5.  To assess the efficacy of i-gel for ventilation, blind tracheal intubation and nasogastric tube insertion.

Authors:  Geeta Bhandari; K S Shahi; Mohd Asad; Nitish Kumar Parmar; Rajni Bhakuni
Journal:  Anesth Essays Res       Date:  2013 Jan-Apr

6.  Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study.

Authors:  Khaled El-Radaideh; Ala A Alhowary; Diab Bani Hani
Journal:  Anesthesiol Res Pract       Date:  2015-12-01

7.  Comparison of clinical performance of the I-gel with LMA proseal.

Authors:  Gaurav Chauhan; Pavan Nayar; Anita Seth; Kapil Gupta; Mamta Panwar; Nidhi Agrawal
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01

8.  Propofol requirement for insertion of I-gel versus laryngeal mask airway: A comparative dose finding study using Dixon's up-and-down method.

Authors:  Nerurkar Aparna Ashay; Shaikh Wasim; Tendolkar Bharati Anil
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Jul-Sep

9.  Use of the i-gel™ supraglottic airway device in a patient with subglottic stenosis -a case report-.

Authors:  Ki Hwa Lee; Eun Su Kang; Jae Wook Jung; Jae Hong Park; Young Gyun Choi
Journal:  Korean J Anesthesiol       Date:  2013-09-25

10.  ED50 of sevoflurane for I-Gel removal in anesthetized children in cataract surgeries using subtenon block.

Authors:  Sameer Sethi; Babita Ghai; Dipika Bansal; Jagat Ram
Journal:  Saudi J Anaesth       Date:  2015 Oct-Dec
View more