Literature DB >> 19264560

Direct analysis of valsartan or candesartan in human plasma and urines by on-line solid phase extraction coupled to electrospray tandem mass spectrometry.

Mikaël Levi1, Grégoire Wuerzner, Eric Ezan, Alain Pruvost.   

Abstract

AT1 receptor blockers are agents for the treatment of hypertension. Rapid and precise assay methods are needed to evaluate possible sub- or overdosage. A direct on-line solid phase extraction coupled to tandem mass spectrometry was developed and validated to determine valsartan (5-2000ng/mL) or candesartan (1-200ng/mL) in human plasma and urines. Both intra- and inter-assay accuracy and precision were in the range 89.2-111% and 0.9-16.9% RSD. Total run time was 4.5min. This on-line clean-up-MS method was found to be robust for the analysis of a high number of samples with unvarying performance.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19264560     DOI: 10.1016/j.jchromb.2009.02.030

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  6 in total

1.  Quantification of Candesartan in Mouse Plasma by MALDI-TOFMS and in Tissue Sections by MALDI-Imaging Using the Stable-Isotope Dilution Technique.

Authors:  Toyofumi Nakanishi; Shinji Takai; Denan Jin; Takayuki Takubo
Journal:  Mass Spectrom (Tokyo)       Date:  2013-06-01

2.  Preparation of hollow porous molecularly imprinted and aluminum(III) doped silica nanospheres for extraction of the drugs valsartan and losartan prior to their quantitation by HPLC.

Authors:  Habibeh Gholami; Mehrorang Ghaedi; Abbas Ostovan; Maryam Arabi; Ahmad Reza Bagheri
Journal:  Mikrochim Acta       Date:  2019-10-16       Impact factor: 5.833

3.  Simultaneous determination of pioglitazone and candesartan in human plasma by LC-MS/MS and its application to a human pharmacokinetic study.

Authors:  Vijaya Kumari Karra; Nageswara Rao Pilli; Jaswanth Kumar Inamadugu; J V L N Seshagiri Rao
Journal:  J Pharm Anal       Date:  2012-01-28

4.  Application of an LC-MS/MS method for the analysis of amlodipine, valsartan and hydrochlorothiazide in polypill for a bioequivalence study.

Authors:  Jaivik V Shah; Jignesh M Parekh; Priyanka A Shah; Priya V Shah; Mallika Sanyal; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2017-06-04

5.  Spectrofluorimetric method for determination of some angiotensin II receptor antagonists.

Authors:  Salwa R El-Shaboury; Samiha A Hussein; Niveen A Mohamed; Mohamed M El-Sutohy
Journal:  J Pharm Anal       Date:  2011-11-10

6.  Determination of candesartan or olmesartan in hypertensive patient plasma using UPLC-MS/MS.

Authors:  Hyeon-Cheol Jeong; Yo-Han Seo; Namyi Gu; Moo Yong Rhee; Kwang-Hee Shin
Journal:  Transl Clin Pharmacol       Date:  2021-12-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.