[Intravertebral pressure during vertebroplasty - an in-vitro study].

S Gravius1, N Kraska, U Maus, T Mumme, P Berdel, M Weisskopf.   

Abstract

INTRODUCTION: Extravasation of bone cement into the vertebral venous system during cement injection has been reported to be a major complication of percutaneous vertebroplasty. Therefore, high injection pressures during cement application into the fractured vertebral body are considered as one possible cause of cement leakage or extravasation. The aim of the current study was to measure the increase in intravertebral pressure caused by cement injection during vertebroplasty compared to the baseline venous pressure for the ascending lumbar vene.
MATERIAL AND METHODS: In context of a cadaver study of 19 unfixed lumbar cadaver spines (L2-L5) [9 female, 10 male, 72 +/- 4.1 years] 19 vertebroplasties have been performed under operative conditions through a transpedicular approach. A manometer was placed in the lateral corticalis of each vertebral body for dynamic pressure measurement during 4 cement application cycles. Average and maximal intravertebral pressures as well as the average intravertebral pressure over the time of cement application ["area under the curve" (AUC)] were calculated.
RESULTS: Average intravertebral pressure (10.9 +/- 12.6 kPa [min.: - 15.2 +/- 24.7 kPa; max.: 56.1 +/- 70.1 kPa]) showed a 13.6-fold increase compared to the baseline venous pressure for the ascending lumbar vein and a 70-fold increase compared to maximal pressure. During the 4 cement application cycles a continuous increase of the average intravertebral pressure over the application cycle (AUC) occurred.
CONCLUSION: The 13.6-fold increase in intravertebral body pressure caused by cement injection during percutaneous vertebroplasty in comparison to the baseline venous pressure for the ascending lumbar vein might be one possible cause of the high rate of extravasation of bone cement reported in the current literature.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19263312     DOI: 10.1055/s-2008-1039114

Source DB:  PubMed          Journal:  Z Orthop Unfall        ISSN: 1864-6697            Impact factor:   0.923


  2 in total

1.  Model of induced leakage of polymethylmethacrilate inside epidural space and prevertebral muscles during vertebroplasty in pigs: clinical, macroscopical, and histological study.

Authors:  Alvaro Silva González; Matías Alfonso Olmos; Carlos Villas Tomé; Marcela Gallegos Angulo
Journal:  Asian Spine J       Date:  2013-09-04

2.  Intraoperative PEEP-ventilation during PMMA-injection for augmented pedicle screws: improvement of leakage rate in spinal surgery.

Authors:  A El Saman; A Kelm; S Meier; A L Sander; K Eichler; I Marzi; H Laurer
Journal:  Eur J Trauma Emerg Surg       Date:  2013-08-20       Impact factor: 3.693

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.