Literature DB >> 19261292

Effects of a surfactant monolayer on the measurement of equilibrium interfacial tension of a drop in extensional flow.

Andrés González-Mancera1, Vijay Kumar Gupta, Mustapha Jamal, Charles D Eggleton.   

Abstract

The effect of surfactant monolayer concentration on the measurement of interfacial surface tension using transient drop deformation methods is studied using the Boundary Integral Method. Emulsion droplets with a surfactant monolayer modeled with the Langmuir equation of state initially in equilibrium are suddenly subjected to axisymmetric extensional flows until a steady state deformation is reached. The external flow is then removed and the retraction of the drops to a spherical equilibrium shape in a quiescent state is simulated. The transient response of the drop to the imposed flow is analyzed to obtain a characteristic response time, tau(s)( *). Neglecting the initial and final stages, the retraction process can be closely approximated by an exponential decay with a characteristic time, tau(r)( *). The strength of the external flow on each model drop is increased in order to investigate the coupled effect of deformation and surfactant distribution on the characteristic relaxation time. Different model drops are considered by varying the internal viscosity and the equilibrium surfactant concentrations from a surfactant free state (clean) to high concentrations approaching the maximum packing limit. The characteristic times obtained from the simulated drop dynamics both in extension and retraction are used to determine an apparent surface tension employing linear theory. In extension the apparent surface tension under predicts the prescribed equilibrium surface tension. The error increases monotonically with the equilibrium surfactant concentration and diverges as the maximum packing limit is approached. In retraction the apparent surface tension under predicts the prescribed equilibrium surface tension depends non-monotonically on the equilibrium surfactant concentration. The error is highest for moderate surfactant concentrations and decreases as the maximum packing limit is approached. It was found that the difference between the prescribed surface tension and the apparent surface tension increased as the viscosity ratio decreased. Differences as large as 40% were seen between the prescribed surface tension and the apparent surface tension predicted by the linear theory.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19261292      PMCID: PMC2683672          DOI: 10.1016/j.jcis.2009.02.004

Source DB:  PubMed          Journal:  J Colloid Interface Sci        ISSN: 0021-9797            Impact factor:   8.128


  4 in total

1.  CFD evaluation of drop retraction methods for the measurement of interfacial tension of surfactant-laden drops.

Authors:  Sachin Velankar; Hua Zhou; Hyun Kyoung Jeon; Christopher W Macosko
Journal:  J Colloid Interface Sci       Date:  2004-04-01       Impact factor: 8.128

2.  Surface dilatational elasticity of poly(oxy ethylene)-based surfactants by oscillation and relaxation measurements of sessile bubbles.

Authors:  Finn Knut Hansen
Journal:  Langmuir       Date:  2007-11-29       Impact factor: 3.882

3.  Time-dependent recovery of passive neutrophils after large deformation.

Authors:  R Tran-Son-Tay; D Needham; A Yeung; R M Hochmuth
Journal:  Biophys J       Date:  1991-10       Impact factor: 4.033

4.  An Adsorption-Desorption-Controlled Surfactant on a Deforming Droplet.

Authors: 
Journal:  J Colloid Interface Sci       Date:  1998-12-01       Impact factor: 8.128

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.