Literature DB >> 19260483

Effectiveness of self-expanding metal stents for malignant antropyloric and duodenal obstruction with a comparison between covered and uncovered stents.

Seungmin Bang1, Hong Jeoung Kim, Jeong Youp Park, Young Soo Park, Myoung Hwan Kim, Seung Woo Park, Yong Chan Lee', Si Young Song.   

Abstract

BACKGROUND/AIMS: We evaluated overall clinical outcomes when self-expanding metal stents were used to treat malignant gastroduodenal obstruction; we also evaluated the differences in technical feasibility, effectiveness, and outcomes between covered and uncovered stents.
METHODOLOGY: We reviewed 134 patients who underwent endoscopic treatment for malignant antropyloric and duodenal obstructions with self-expanding metal stents.
RESULTS: In all but two cases, the procedures were successful in restoring passage through the obstruction. Forty-two patients (31.8%) experienced stent failure during the follow-up period (23/79 (29.1%) with uncovered stents, 19/53 (35.8%) with covered stents). Stent migration was the most common cause for failure in covered stents (73.7%), while tumor ingrowth was the most common cause in uncovered stents (52.2%). The median technical survival in the uncovered stent group was similar to covered stent group (253 days vs. 247 days, p>0.05). Improvement of oral intake was associated with improvement in performance score, which was significantly improved following stent insertion (p<0.05). In addition, patients whose performance score was improved by stenting had better survival than those who did not (median survival 173 days vs. 74 days, p<0.05).
CONCLUSIONS: Endoscopic stenting for malignant gastroduodenal obstruction appears to be an effective therapeutic modality in terminally ill patients, irrespective of the type of stent. Improvement in stent technology will improve patients' oral intake, which in turn will improve patients' quality of life and survival rate.

Entities:  

Mesh:

Year:  2008        PMID: 19260483

Source DB:  PubMed          Journal:  Hepatogastroenterology        ISSN: 0172-6390


  6 in total

1.  SEMS vs cSEMS in duodenal and small bowel obstruction: high risk of migration in the covered stent group.

Authors:  Oliver Waidmann; Jörg Trojan; Mireen Friedrich-Rust; Christoph Sarrazin; Wolf Otto Bechstein; Frank Ulrich; Stefan Zeuzem; Jörg Gerhard Albert
Journal:  World J Gastroenterol       Date:  2013-10-07       Impact factor: 5.742

2.  Outcomes of endoscopically inserted self-expandable metal stents in malignancy according to the type of stent and the site of obstruction.

Authors:  Kyoungwon Jung; Ji Yong Ahn; Hwoon-Yong Jung; Charles J Cho; Hee Kyong Na; Kee Wook Jung; Jeong Hoon Lee; Do Hoon Kim; Kee Don Choi; Ho June Song; Gin Hyug Lee; Jin-Ho Kim
Journal:  Surg Endosc       Date:  2015-12-29       Impact factor: 4.584

3.  Comparison of uncovered and covered stents for the treatment of malignant duodenal obstruction caused by pancreaticobiliary cancer.

Authors:  Sang Myung Woo; Dong Hwan Kim; Woo Jin Lee; Kyung Woo Park; Sang-Jae Park; Sung-Sik Han; Tae Hyun Kim; Young Hwan Koh; Hyun Bum Kim; Eun Kyung Hong
Journal:  Surg Endosc       Date:  2013-01-04       Impact factor: 4.584

Review 4.  Covered versus uncovered self-expandable metallic stents for palliation of malignant gastric outlet obstruction: a systematic review and meta-analysis.

Authors:  Ya-min Pan; Ji Pan; Li-kun Guo; Min Qiu; Jia-jun Zhang
Journal:  BMC Gastroenterol       Date:  2014-09-30       Impact factor: 3.067

5.  A Multicenter Randomized Controlled Trial of Malignant Gastric Outlet Obstruction: Tailored Partially Covered Stents (Placed Fluoroscopically) versus Standard Uncovered Stents (Placed Endoscopically).

Authors:  Ding Shi; Feng Ji; Yin-Su Bao; Yong-Pan Liu
Journal:  Gastroenterol Res Pract       Date:  2014-12-24       Impact factor: 2.260

6.  A pilot study of novel duodenal covered self-expandable metal stent fixation.

Authors:  Yasuki Hori; Kazuki Hayashi; Itaru Naitoh; Katsuyuki Miyabe; Makoto Natsume; Michihiro Yoshida; Hiromi Kataoka
Journal:  Sci Rep       Date:  2021-10-05       Impact factor: 4.379

  6 in total