Ceramic pressed to metal versus feldspathic porcelain fused to metal: a comparative study of bond strength.

Bhavani Venkatachalam1, Gary R Goldstein, Mitchell S Pines, Eugene L Hittelman.   

Abstract

PURPOSE: The aim of this study was to compare the debond/crack initiation strength (D/CIS) of a leucite-based low-fusing ceramic pressed (PC) to metal and feldspathic porcelain (FP) fused to metal.
MATERIALS AND METHODS: Forty rectangular metal specimens, 20 noble alloy (NA; gold-palladium) and 20 base metal alloy (BA; cobalt-chromium) were fabricated per ISO 9693:1999 standards (25.0 mm x 0.5 mm x 3.0 mm). Ten samples in each group received FP and the remaining 10 received PC. The samples in the PC group underwent wax pattern build-ups and subsequent investing and casting. The ceramic dimensions in all four groups were 8.0 mm x 1.0 mm x 3.0 mm. The final metal-ceramic specimen thickness was 1.5 mm. All specimens were subject to the Schwickerath crack-initiation three-point bending test at a crosshead speed of 1.5 mm/min. Metal-ceramic fracture loads were recorded in Newtons and D/CIS was calculated using the formula: tau(b) = k x Ffail.
RESULTS: Mean D/CIS were as follows: BA-FP: 36.11 +/- 2.31 MPa, NA-FP: 42.64 +/- 1.94 MPa, BA-PC: 37.47 +/- 6.02 MPa, and NA-PC: 47.94 +/- 3.92 MPa. A 2-way ANOVA revealed no significant difference in D/CIS values between the four groups. A statistically significant difference was noted when comparing the mean D/CIS values obtained between the two metal alloys used (NA: 45.29 MPa and BA: 36.79 MPa).
CONCLUSION: No differences (P > .05) in mean D/CIS were found between the low-fusing ceramic pressed to metal and the FP fused to metal. A higher mean D/CIS (P > .05) was found for the NA compared to the BA, with both ceramics tested.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19260436

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  4 in total

1.  Post-fatigue fracture resistance of metal core crowns: press-on metal ceramic versus a conventional veneering system.

Authors:  M Fernanda Solá-Ruiz; Rubén Agustín-Panadero; Carlos Campos-Estellés; Carlos Labaig-Rueda
Journal:  J Clin Exp Dent       Date:  2015-04-01

2.  Fabrication of a metal-ceramic crown to fit an existing partial removable dental prosthesis using ceramic pressed to metal technique: a clinical report.

Authors:  Jae-Min Seo; Seung-Geun Ahn
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

3.  Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy.

Authors:  Yoshito Minesaki; Sadaaki Murahara; Yutaro Kajihara; Yoshihisa Takenouchi; Takuo Tanaka; Shiro Suzuki; Hiroyuki Minami
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

4.  Evaluation of Bond Strength of Pressed and Layered Veneering Ceramics to Nickel-Chromium Alloy.

Authors:  Mitra Farzin; Amir Alireza Khaledi; Behnam Malekpour; Mohammad Hassan Naseri
Journal:  J Dent (Shiraz)       Date:  2015-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.