Literature DB >> 19260427

Fracture-load values of all-ceramic cantilevered FPDs with different framework designs.

Brigitte Ohlmann1, Katrin Marienburg, Olaf Gabbert, Alexander Hassel, Herbert Gilde, Peter Rammelsberg.   

Abstract

The purpose of this study was to evaluate the fracture-load values of cantilevered all-ceramic fixed partial dentures (FPDs). Fifty FPDs were manufactured using a zirconia frame to replace a missing molar. The FPDs were divided into five groups, each with a different framework design. After thermocycling and mechanical loading, the load to fracture was measured. The Mann-Whitney Utest was used for statistical analysis. The mean fracture-load values for the test groups ranged from 346 to 548 N. Reinforcement of the shoulder on the oral side of the occlusal wall resulted in higher fracture load values, while increasing the wall thickness of the distal abutment did not improve fracture resistance. The results indicate that all-ceramic cantilever FPDs cannot yet be recommended for clinical replacement of a missing molar.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19260427

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  9 in total

1.  Are implants more reliable than severely compromised endodontically treated teeth as abutments for zirconia-based FPDs? : In vitro results of long-term preclinical load simulation.

Authors:  M Naumann; C Hohmann; A Happe; F Beuer; R Frankenberger; R Seemann; M Rosentritt
Journal:  Clin Oral Investig       Date:  2012-10-27       Impact factor: 3.573

2.  Impact of simulated reduced alveolar bone support, increased tooth mobility, and distal post-supported, root-treated abutment tooth on load capability of all-ceramic zirconia-supported cantilever FDP.

Authors:  M Naumann; M von Stein-Lausnitz; M Rosentritt; C Walter; H Meyer-Lückel; G Sterzenbach
Journal:  Clin Oral Investig       Date:  2018-02-06       Impact factor: 3.573

3.  Fracture behaviour of implant-implant- and implant-tooth-supported all-ceramic fixed dental prostheses utilising zirconium dioxide implant abutments.

Authors:  Frank Philipp Nothdurft; Sabine Merker; Peter Reinhard Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-05       Impact factor: 3.573

4.  The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study.

Authors:  Seung-Ryong Ha; Sung-Hun Kim; Jung-Suk Han; Seung-Hyun Yoo; Se-Chul Jeong; Jai-Bong Lee; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

5.  Fracture Load of CAD/CAM Fabricated Cantilever Implant-Supported Zirconia Framework: An In Vitro Study.

Authors:  Ibraheem F Alshiddi; Syed Rashid Habib; Muhammad Sohail Zafar; Salwa Bajunaid; Nawaf Labban; Mohammed Alsarhan
Journal:  Molecules       Date:  2021-04-13       Impact factor: 4.411

6.  Effect of framework design on fracture resistance of zirconium oxide posterior fixed partial dentures.

Authors:  Hadi Salimi; Ramin Mosharraf; Omid Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-11

7.  Maxillary cement retained implant supported monolithic zirconia prosthesis in a full mouth rehabilitation: a clinical report.

Authors:  Ramtin Sadid-Zadeh; Perng-Ru Liu; Ruth Aponte-Wesson; Sandra J O'Neal
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

8.  Rationale for the use of CAD/CAM technology in implant prosthodontics.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  Int J Dent       Date:  2013-04-16

Review 9.  Trends in computer-aided manufacturing in prosthodontics: a review of the available streams.

Authors:  Jaafar Abduo; Karl Lyons; Mohammed Bennamoun
Journal:  Int J Dent       Date:  2014-04-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.