Literature DB >> 19260242

Length and landmark of A1 pulley in hand: an anatomical study.

Yolchai Jongjirasiri1.   

Abstract

OBJECTIVE: The purpose of the present study was to identify length and landmark of proximal of A1 pulley in hand. MATERIAL AND
METHOD: An anatomical study of the length and landmark of A1 pulley in hand was performed in 510 fingers and thumbs from 51 preserved cadavers. There were 25 females and 26 males whose ages at the time of death ranged from 48 to 89 years.
RESULTS: The lengths of A1 pulley were 5.30 +/- 0.53 mm in average of thumbs and 6.32 +/- 0.17, 6.58 +/- 0.19, 6.32 +/- 0.20, and 5.30 +/- 0.49 for the index, middle, ring, and small finger respectively. The average of all fingers were 6.13 +/- 0.17 mm. The margin from the proximal edge of A1 pulley related to the perpendicular line from posterior superior prominent of metacarpal head to the volar aspect of its fingers, which was in the same line for 327 (64.1%) fingers and thumbs, and for 464 (91.0%) fingers and thumbs were differences < or = 1 mm, and for 509 (99.8%) were differences < or = 2mm to proximal edge of A1 pulley of its finger and thumb.
CONCLUSION: The posterior superior prominent of metacarpal head line in perpendicular to the volar aspect of its finger and thumb may be used as an anatomical landmark to predict of the proximal edge of A1 pulley with reasonable accuracy. The length of A1 pulley can serve as an important guide for the distal termination ofA1 pulley release.

Mesh:

Year:  2009        PMID: 19260242

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  7 in total

1.  The Relationship Between the Intercrease Line and the A1 Digital Pulley: A Cadaveric Study.

Authors:  Colyn J Watkins; Nikola Zivaljevic; Kyle R Eberlin; Michael Rivlin; Chaitanya S Mudgal
Journal:  Hand (N Y)       Date:  2016-07-28

2.  A comparative study of A1 pulley compliance.

Authors:  Wen-Lin Tung; Chunfeng Zhao; Yuichi Yoshii; Peter C Amadio; Fong-Chin Su; Kai-Nan An
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-04-02       Impact factor: 2.063

3.  Topographic anatomical landmarks for pulley system of the thumb.

Authors:  Dhivyalakshmi Gnanasekaran; Raveendranath Veeramani; Aravindhan Karuppusamy
Journal:  Surg Radiol Anat       Date:  2018-04-18       Impact factor: 1.246

4.  Trigger Finger? Just Shoot!

Authors:  Stephen P Merry; Jason S O'Grady; Christopher L Boswell
Journal:  J Prim Care Community Health       Date:  2020 Jan-Dec

5.  Morphometric study of pulleys of the thumb.

Authors:  Dhivyalakshmi Gnanasekaran; Raveendranath Veeramani; Aravindhan Karuppusamy
Journal:  Anat Cell Biol       Date:  2018-06-27

6.  Ultrasound-Guided Percutaneous A1 Pulley Release by Acupotomy (Needle-Knife): A Cadaveric Study of Safety and Efficacy.

Authors:  Jiaxuan Yang; Bin Ma; Hao Zhong; Yue Zhang; Jiang Zhu; Yong Ni
Journal:  J Pain Res       Date:  2022-02-09       Impact factor: 3.133

7.  A Cadaveric Study of the Thread Trigger Finger Release: The First Annular Pulley Transection Through Thread Transecting Technique.

Authors:  Danqing Guo; Danzhu Guo; Joseph Guo; Logan C McCool; Brionn Tonkin
Journal:  Hand (N Y)       Date:  2017-03-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.