Literature DB >> 19260051

Concentric and single fiber needle electrodes yield comparable jitter results in myasthenia gravis.

Maria E Farrugia1, Andrew I Weir, Marie Cleary, Sarah Cooper, Richard Metcalfe, Arup Mallik.   

Abstract

The single fiber needle electrode (SFNE), which is designed to isolate single muscle fiber action potentials, has played an important role in the diagnosis of myasthenia gravis (MG). However, the concentric needle electrode (CNE) has been recently adopted by some workers to study neuromuscular instability in MG, and reference data have also been obtained in healthy subjects. In this study we wanted to establish whether data acquired using the SFNE is comparable to that obtained using the CNE when studying patients with MG. We established reference data for our laboratory using the CNE for orbicularis oculi (OO) and extensor digitorum communis (EDC). We compared data from 24 MG patients using both SFNE and CNE and found no significant differences in mean jitter values for either muscles. We correlated the neurophysiological data obtained by either electrode with various clinical assessments, the ice pack test, OO and EDC strength measurement, and MGFA classification of disease, and we found no significant relation. We compared discomfort scores for the two needle electrodes for each muscle and found that the discomfort scores for CNE are significantly lower (P = 0.0004). We conclude that the CNE is a useful alternative electrode for studying single fiber potentials, but more reference data from normal control subjects is desirable. Muscle Nerve, 2008.

Entities:  

Mesh:

Year:  2009        PMID: 19260051     DOI: 10.1002/mus.21151

Source DB:  PubMed          Journal:  Muscle Nerve        ISSN: 0148-639X            Impact factor:   3.217


  7 in total

1.  Application of futility analysis to refine jitter recordings in myasthenia gravis.

Authors:  Pushpa Narayanaswami; Norberto Pantoja-Galicia; Rebecca A Betensky; Seward B Rutkove
Journal:  Muscle Nerve       Date:  2012-04       Impact factor: 3.217

2.  Jitter Values on Voluntary Active Periocular Muscles of Healthy Subjects with Conventional (37 mm) Concentric Needle Electrode.

Authors:  Leyla Baysal Kiraç; Elif Kocasoy Orhan; Saygın Gönderten; Mehmet Barış Baslo; Ali Emre Öge
Journal:  Noro Psikiyatr Ars       Date:  2016-06-01       Impact factor: 1.339

3.  Clinical and CN-SFEMG evaluation of neostigmine test in myasthenia gravis.

Authors:  Giorgia Sciacca; Ester Reggio; Giovanni Mostile; Alessandra Nicoletti; Filippo Drago; Salvatore Salomone; Mario Zappia
Journal:  Neurol Sci       Date:  2018-01-12       Impact factor: 3.307

4.  Single-fiber EMG: A review.

Authors:  V Arul Selvan
Journal:  Ann Indian Acad Neurol       Date:  2011-01       Impact factor: 1.383

5.  Concentric Needle Jitter in 97 Myasthenia Gravis Patients.

Authors:  João Aris Kouyoumdjian; Gabriel Pina Paiva; Erik Stålberg
Journal:  Front Neurol       Date:  2020-11-13       Impact factor: 4.003

6.  Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle.

Authors:  João Aris Kouyoumdjian; Carla Renata Graca
Journal:  Front Neurol       Date:  2022-07-22       Impact factor: 4.086

7.  Quantitating Changes in Jitter and Spike Number Using Concentric Needle Electrodes in Amyotrophic Lateral Sclerosis Patients.

Authors:  Ming-Sheng Liu; Jing-Wen Niu; Yi Li; Yu-Zhou Guan; Li-Ying Cui
Journal:  Chin Med J (Engl)       Date:  2016-05-05       Impact factor: 2.628

  7 in total