Literature DB >> 19254558

Impedance-based monitoring of ongoing cardiomyocyte death induced by tumor necrosis factor-alpha.

Yiling Qiu1, Ronglih Liao, Xin Zhang.   

Abstract

Deregulated cardiomyocyte death is a critical risk factor in a variety of cardiovascular diseases. Although various assays have been developed to detect cell responses during cell death, the capability of monitoring cell detachment will enhance the understanding of death processes by providing instant information at its early phase. In this work, we developed an impedance-sensing assay for real-time monitoring of cardiomyocyte death induced by tumor necrosis factor-alpha based on recording the change in cardiomyocyte adhesion to extracellular matrix. Electrochemical impedance spectroscopy was employed in impedance data processing, followed by calibration with the electrical cell-substrate impedance-sensing technique. The adhesion profile of cardiomyocytes undergoing cell death processes was recorded as the time course of equivalent cell-substrate distance. The cell detachment was detected with our assay and proved related to cell death in the following experiments, indicating its advantage against the conventional assays, such as Trypan blue exclusion. An optimal concentration of tumor necrosis factor-alpha (20 ng/mL) was determined to induce cardiomyocyte apoptosis rather than the combinative cell death of necrosis and apoptosis by comparing the concentration-related adhesion profiles. The cardiomyocytes undergoing apoptosis experienced an increase of cell-substrate distance from 59.1 to 89.2 nm within 24 h. The early change of cell adhesion was proved related to cardiomyocyte apoptosis in the following TUNEL test at t = 24 h, which suggested the possibility of early and noninvasive detection of cardiomyocyte apoptosis.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19254558      PMCID: PMC2717358          DOI: 10.1016/j.bpj.2008.11.036

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  26 in total

1.  High-throughput assessment of calcium sensitivity in skinned cardiac myocytes.

Authors:  C C Lim; M H Helmes; D B Sawyer; M Jain; R Liao
Journal:  Am J Physiol Heart Circ Physiol       Date:  2001-08       Impact factor: 4.733

2.  An in-depth analysis of electric cell-substrate impedance sensing to study the attachment and spreading of mammalian cells.

Authors:  Caide Xiao; Bernard Lachance; Geoffrey Sunahara; John H T Luong
Journal:  Anal Chem       Date:  2002-03-15       Impact factor: 6.986

3.  Assessment of cytotoxicity using electric cell-substrate impedance sensing: concentration and time response function approach.

Authors:  Caide Xiao; Bernard Lachance; Geoffrey Sunahara; John H T Luong
Journal:  Anal Chem       Date:  2002-11-15       Impact factor: 6.986

4.  Real-time monitoring primary cardiomyocyte adhesion based on electrochemical impedance spectroscopy and electrical cell-substrate impedance sensing.

Authors:  Yiling Qiu; Ronglih Liao; Xin Zhang
Journal:  Anal Chem       Date:  2008-01-24       Impact factor: 6.986

5.  Monitoring fibroblast behavior in tissue culture with an applied electric field.

Authors:  I Giaever; C R Keese
Journal:  Proc Natl Acad Sci U S A       Date:  1984-06       Impact factor: 11.205

6.  Structure of laminin substrate modulates cellular signaling for neuritogenesis.

Authors:  Elisabete Freire; Flávia C A Gomes; Rafael Linden; Vivaldo Moura Neto; Tatiana Coelho-Sampaio
Journal:  J Cell Sci       Date:  2002-12-15       Impact factor: 5.285

7.  Tumor necrosis factor-alpha induces apoptosis via inducible nitric oxide synthase in neonatal mouse cardiomyocytes.

Authors:  W Song; X Lu; Q Feng
Journal:  Cardiovasc Res       Date:  2000-02       Impact factor: 10.787

8.  Bioelectrical impedance assay to monitor changes in cell shape during apoptosis.

Authors:  Silke Arndt; Jochen Seebach; Katherina Psathaki; Hans-Joachim Galla; Joachim Wegener
Journal:  Biosens Bioelectron       Date:  2004-01-15       Impact factor: 10.618

9.  Fibroblast cells: a sensing bioelement for glucose detection by impedance spectroscopy.

Authors:  Chaker Tlili; Karine Reybier; Alain Géloën; Laurence Ponsonnet; Claude Martelet; Hafedh Ben Ouada; Michel Lagarde; Nicole Jaffrezic-Renault
Journal:  Anal Chem       Date:  2003-07-15       Impact factor: 6.986

10.  Electrical stimulation improves insulin responses in a human skeletal muscle cell model of hyperglycemia.

Authors:  Vigdis Aas; Siri Torblå; Merethe H Andersen; Jørgen Jensen; Arild Chr Rustan
Journal:  Ann N Y Acad Sci       Date:  2002-06       Impact factor: 5.691

View more
  7 in total

1.  A novel broadband impedance method for detection of cell-derived microparticles.

Authors:  Vadim Lvovich; Sowmya Srikanthan; Roy L Silverstein
Journal:  Biosens Bioelectron       Date:  2010-08-03       Impact factor: 10.618

2.  Machine learning plus optical flow: a simple and sensitive method to detect cardioactive drugs.

Authors:  Eugene K Lee; Yosuke K Kurokawa; Robin Tu; Steven C George; Michelle Khine
Journal:  Sci Rep       Date:  2015-07-03       Impact factor: 4.379

3.  Crosstalk of cardiomyocytes and fibroblasts in co-cultures.

Authors:  J Rother; C Richter; L Turco; F Knoch; I Mey; S Luther; A Janshoff; E Bodenschatz; M Tarantola
Journal:  Open Biol       Date:  2015-06       Impact factor: 6.411

4.  Electrical Impedance Monitoring of C2C12 Myoblast Differentiation on an Indium Tin Oxide Electrode.

Authors:  Ilhwan Park; Yeonhee Hong; Young-Hoo Jun; Ga-Yeon Lee; Hee-Sook Jun; Jae-Chul Pyun; Jeong-Woo Choi; Sungbo Cho
Journal:  Sensors (Basel)       Date:  2016-12-05       Impact factor: 3.576

5.  Zinc oxide nanorod field effect transistor for long-time cellular force measurement.

Authors:  Xianli Zong; Rong Zhu
Journal:  Sci Rep       Date:  2017-03-08       Impact factor: 4.379

6.  Nanostructured gold microelectrodes for SERS and EIS measurements by incorporating ZnO nanorod growth with electroplating.

Authors:  Xianli Zong; Rong Zhu; Xiaoliang Guo
Journal:  Sci Rep       Date:  2015-11-12       Impact factor: 4.379

Review 7.  Recent Advances in Monitoring Cell Behavior Using Cell-Based Impedance Spectroscopy.

Authors:  Qusai Hassan; Soha Ahmadi; Kagan Kerman
Journal:  Micromachines (Basel)       Date:  2020-06-13       Impact factor: 2.891

  7 in total