Literature DB >> 19253238

Ultrasound biomicroscopy and optical coherence tomography imaging of filtering blebs after deep sclerectomy with new collagen implant.

Florent Aptel1, Sophie Dumas, Philippe Denis.   

Abstract

PURPOSE: To identify the clinical and anatomic characteristics of filtering blebs after glaucoma surgery with a new biodegradable collagen implant, Ologen, using ultrasound biomicroscopy (UBM) and Visante anterior segment optical coherence tomography (OCT).
METHODS: The authors conducted a prospective interventional case series in 15 eyes with openangleglaucoma. The authors performed limbal-based deep sclerectomy with Ologen implantation in the scleral bed. UBM, Visante anterior segment OCT, and a complete ophthalmic examination were performed at each follow-up visit, at 1 day, and 1, 4, and 12 weeks postoperatively.
RESULTS: Intraocular pressure (IOP) was significantly reduced (p<0.001) from a mean preoperative value of 24.2-/+6.8 mmHg (n=2.82 glaucoma medications) to a mean postoperative value of 8.1-/+1.2 (n=0), 8.5-/+1.3 (n=0), 11.7-/+3.2 (n=0), and 14.2-/+3.9 mmHg (n=0.33) at 1 day, and 1, 4, and 12 weeks, respectively. Lower IOP correlated with bleb height and low trabeculocorneal membrane thickness (r=0.79, p<0.01, r=0.91, p<0.001) based on UBM examination. Lower IOP correlated with thin bleb wall, large subconjunctival fluid spaces, and low bleb tissue reflectivity (r=0.81, p<0.01, p<0.001, and p<0.001) based on OCT examination. No postoperative complications were reported.
CONCLUSIONS: UBM and OCT examinations are useful methods to evaluate outflow mechanisms after glaucoma surgery. Deep sclerectomy with Ologen implantation seems to be an effective and well-tolerated method to reduce IOP.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19253238     DOI: 10.1177/112067210901900208

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  15 in total

1.  Imaging of trabeculectomy blebs with Visante anterior segment optical coherence tomography after digital ocular compression.

Authors:  Hae-Young Lopilly Park; Myung Douk Ahn
Journal:  Jpn J Ophthalmol       Date:  2011-11-26       Impact factor: 2.447

2.  Capsule excision and Ologen implantation for revision after glaucoma drainage device surgery.

Authors:  André Rosentreter; Anne C Mellein; Walter W Konen; Thomas S Dietlein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-04-20       Impact factor: 3.117

3.  Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: a 24-month, randomized clinical trial.

Authors:  S Cillino; F Di Pace; G Cillino; A Casuccio
Journal:  Eye (Lond)       Date:  2011-09-16       Impact factor: 3.775

4.  Effect of filtering bleb dimensions on postoperative intraocular pressure in deep sclerectomy with collagen implant: a comparative study.

Authors:  Hany Elmekawey; Ahmed Abdelrahman; Mohamad S Kotb; Diia Alden Mostafa
Journal:  Int Ophthalmol       Date:  2019-07-18       Impact factor: 2.031

5.  Deep sclerectomy with mitomycin C in eyes with failed glaucoma surgery and pseudophakia.

Authors:  N Anand; D Wechsler
Journal:  Eye (Lond)       Date:  2011-10-07       Impact factor: 3.775

6.  Anterior-segment imaging for assessment of glaucoma.

Authors:  Roxana Ursea; Ronald H Silverman
Journal:  Expert Rev Ophthalmol       Date:  2010-02-01

7.  Outcomes of combined phacoemulsification and deep sclerectomy: a 10-year UK single-centre study.

Authors:  K Mercieca; B Shevade; N Anand
Journal:  Eye (Lond)       Date:  2015-09-04       Impact factor: 3.775

8.  Long-term outcomes of needle revision of failing deep sclerectomy blebs.

Authors:  Antigoni Koukkoulli; Fayyaz Musa; Nitin Anand
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-10-11       Impact factor: 3.117

9.  Biodegradable PTLGA Terpolymers versus Collagen Implants Used as an Adjuvant in Trabeculectomy in Rabbit Eye.

Authors:  Weiran Niu; Guanglin Shen; Yuanzhi Yuan; Xiaoping Ma; Suming Li; Jingzhao Wang; Zhongyong Fan; Lan Liao
Journal:  J Ophthalmol       Date:  2015-11-30       Impact factor: 1.909

Review 10.  Anterior segment optical coherence tomography imaging of conjunctival filtering blebs after glaucoma surgery.

Authors:  Rodolfo Mastropasqua; Vincenzo Fasanella; Luca Agnifili; Claudia Curcio; Marco Ciancaglini; Leonardo Mastropasqua
Journal:  Biomed Res Int       Date:  2014-07-20       Impact factor: 3.411

View more