AIMS: A reduction in tricuspid annular plane systolic excursion (TAPSE) and peak systolic velocity (PSV) of tricuspid annulus after cardiac surgery is a well-known phenomenon, even though its origin is not well established. Recently, a new three-dimensional (3D) echocardiographic software adapted for right ventricular (RV) analysis has been validated. Aims of this study were to evaluate RV function in patients with mitral valve prolapse undergoing surgical valvular repair and to compare and correlate 3D RV ejection fraction (RVEF) with TAPSE and PSV before and after surgery. METHODS AND RESULTS: Forty patients were studied by transthoracic 2D and 3D echocardiography pre- and 3, 6, and 12 months post-surgery. TAPSE (15.5 +/- 3, 16.5 +/- 3, and 18.5 +/- 4 mm at 3, 6, and 12 months, respectively) and PSV (11.9 +/- 2, 12 +/- 2, and 12.8 +/- 3 cm/s at 3, 6, and 12 months, respectively) were significantly (P < 0.001) lower after surgery in comparison with pre-surgical values (TAPSE: 25.3 +/- 4 mm; PSV: 17.8 +/- 4 cm/s). On the contrary, pre-operative RVEF (58.4 +/- 4%) did not change after surgery (56.9 +/- 5, 59.5 +/- 5, and 58.5 +/- 5% at each step). CONCLUSION: Despite the post-operative reduction of RV performance along the long axis suggested by TAPSE and PSV, the absence of a decrease in 3D RVEF leads to caution in the interpretation of these 2D and Doppler parameters after cardiac surgery, supporting the hypothesis of geometrical rather than functional changes in the right ventricle.
AIMS: A reduction in tricuspid annular plane systolic excursion (TAPSE) and peak systolic velocity (PSV) of tricuspid annulus after cardiac surgery is a well-known phenomenon, even though its origin is not well established. Recently, a new three-dimensional (3D) echocardiographic software adapted for right ventricular (RV) analysis has been validated. Aims of this study were to evaluate RV function in patients with mitral valve prolapse undergoing surgical valvular repair and to compare and correlate 3D RV ejection fraction (RVEF) with TAPSE and PSV before and after surgery. METHODS AND RESULTS: Forty patients were studied by transthoracic 2D and 3D echocardiography pre- and 3, 6, and 12 months post-surgery. TAPSE (15.5 +/- 3, 16.5 +/- 3, and 18.5 +/- 4 mm at 3, 6, and 12 months, respectively) and PSV (11.9 +/- 2, 12 +/- 2, and 12.8 +/- 3 cm/s at 3, 6, and 12 months, respectively) were significantly (P < 0.001) lower after surgery in comparison with pre-surgical values (TAPSE: 25.3 +/- 4 mm; PSV: 17.8 +/- 4 cm/s). On the contrary, pre-operative RVEF (58.4 +/- 4%) did not change after surgery (56.9 +/- 5, 59.5 +/- 5, and 58.5 +/- 5% at each step). CONCLUSION: Despite the post-operative reduction of RV performance along the long axis suggested by TAPSE and PSV, the absence of a decrease in 3D RVEF leads to caution in the interpretation of these 2D and Doppler parameters after cardiac surgery, supporting the hypothesis of geometrical rather than functional changes in the right ventricle.
Authors: Lars Grønlykke; André Korshin; Frederik Holmgaard; Sven Morten Kjøller; Finn Gustafsson; Jens Chr Nilsson; Hanne Berg Ravn Journal: Int J Cardiovasc Imaging Date: 2019-05-02 Impact factor: 2.357
Authors: Ibrahim Sultan; Arturo Cardounel; Islam Abdelkarim; Arman Kilic; Andrew D Althouse; Michael S Sharbaugh; Aman Gupta; Jeff Xu; Miho Fukui; Marc A Simon; John T Schindler; Joon S Lee; Thomas G Gleason; João L Cavalcante Journal: Heart Date: 2018-08-09 Impact factor: 5.994
Authors: Viola Weidenmann; N Bryce Robinson; Lisa Q Rong; Irbaz Hameed; Ajita Naik; Mahmoud Morsi; Philippe Grieshaber; Andreas Böning; Leonard N Girardi; Mario Gaudino Journal: Int J Surg Date: 2020-05-19 Impact factor: 6.071
Authors: A Korshin; L Grønlykke; J C Nilsson; H Møller-Sørensen; N Ihlemann; M Kjøller; S Damgaard; P Lehnert; C Hassager; J Kjaergaard; H B Ravn Journal: Int J Cardiovasc Imaging Date: 2018-01-30 Impact factor: 2.357