Literature DB >> 19251099

Gated irradiation with scanned particle beams.

Christoph Bert1, Alexander Gemmel, Nami Saito, Eike Rietzel.   

Abstract

PURPOSE: To demonstrate mitigation of the interplay effects of scanned particle beams and residual target motion within a gating window by increased overlap of pencil beams. METHODS AND MATERIALS: Lateral overlap was increased by increasing the pencil beam widths or by decreasing the distance between the pencil beams (scan grid). Longitudinal overlap was increased by reducing the distance between iso-range slices. For scanned carbon ion beams, simulation studies were performed and validated experimentally to determine the required parameters for different residual motion characteristics. The dose distributions were characterized by the maximal local deviations representing local over- and underdosage.
RESULTS: For residual lateral motion, the local deviations were <5% for 2, 4, and 7 mm residual motion within the gating window for a 2-mm scan grid and pencil beams of 10, 14, and 18 mm full width at half maximum, respectively. Decreasing the iso-range slice distance from 3 mm to 1 mm effectively mitigated <or=10 mm water-equivalent range changes. Experimental data reproduced the simulation results.
CONCLUSION: In charged particle therapy with a scanned beam, interplay effects between gated beam delivery and residual target motion can be decreased effectively by increasing the overlap between pencil beams laterally, as well as longitudinally.

Entities:  

Mesh:

Year:  2009        PMID: 19251099     DOI: 10.1016/j.ijrobp.2008.11.014

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  20 in total

1.  [Translational uroradio-oncology].

Authors:  S E Combs; J Debus
Journal:  Urologe A       Date:  2013-09       Impact factor: 0.639

Review 2.  [Strategies for preoperative downsizing in patients with local nonresectable pancreatic cancer].

Authors:  S E Combs; D Habermehl; J Werner; M W Büchler; J Debus
Journal:  Chirurg       Date:  2011-11       Impact factor: 0.955

Review 3.  Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview.

Authors:  Radhe Mohan; Indra J Das; Clifton C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-10-01       Impact factor: 7.038

4.  Dynamically accumulated dose and 4D accumulated dose for moving tumors.

Authors:  Heng Li; Yupeng Li; Xiaodong Zhang; Xiaoqiang Li; Wei Liu; Michael T Gillin; X Ronald Zhu
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

5.  Four-dimensional Monte Carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments.

Authors:  Stephen Dowdell; Clemens Grassberger; Harald Paganetti
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

6.  Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters.

Authors:  S Dowdell; C Grassberger; G C Sharp; H Paganetti
Journal:  Phys Med Biol       Date:  2013-05-20       Impact factor: 3.609

7.  Validation of dose distribution for liver tumors treated with real-time-image gated spot-scanning proton therapy by log data based dose reconstruction.

Authors:  Takahiro Yamada; Seishin Takao; Hidenori Koyano; Hideaki Nihongi; Yusuke Fujii; Shusuke Hirayama; Naoki Miyamoto; Taeko Matsuura; Kikuo Umegaki; Norio Katoh; Isao Yokota; Hiroki Shirato; Shinichi Shimizu
Journal:  J Radiat Res       Date:  2021-07-10       Impact factor: 2.724

8.  Scanned carbon beam irradiation of moving films: comparison of measured and calculated response.

Authors:  Christoph Bert; Daniel Richter; Marco Durante; Eike Rietzel
Journal:  Radiat Oncol       Date:  2012-04-02       Impact factor: 3.481

Review 9.  Physics of Particle Beam and Hypofractionated Beam Delivery in NSCLC.

Authors:  Harald Paganetti; Clemens Grassberger; Gregory C Sharp
Journal:  Semin Radiat Oncol       Date:  2021-04       Impact factor: 5.421

10.  Evaluation of the dose variation for prostate heavy charged particle therapy using four-dimensional computed tomography.

Authors:  Motoki Kumagai; Tohru Okada; Shinichiro Mori; Susumu Kandatsu; Hiroshi Tsuji
Journal:  J Radiat Res       Date:  2012-12-21       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.