Literature DB >> 19249487

Reappraisal of HLA antibody analysis and crossmatching in kidney transplantation.

P-C Lee1, M Ozawa, C-J Hung, Y-J Lin, S-S Chang, T-C Chou.   

Abstract

Enzyme-linked immunosorbent assay (ELISA) and flow cytometric techniques have been introduced to overcome the limited sensitivity and specificity of the CDC assay. This retrospective study used lambda antigen tray-mixed screening and Luminex HLA class I and II specificity assays to re-examine: (1) the accuracy with which detection of HLA antibody and specificity by ELISA predicts pretransplantation National Institutes of Health (NIH)/Centers for Disease Control and Prevention (CDC) crossmatch; and (2) a comparison of Luminex and ELISA methods to detect HLA antibodies. Sera from 481 patients awaiting kidney transplantation were tested using the ELISA method lambda antigen tray-mixed and using NIH-CDC to determine how well HLA antibodies detected using ELISA predicted crossmatches using CDC. Pretransplantation sera from 48 patients with follow-up data were retested using both ELISA lambda antigen tray-mixed and Luminex to compare the efficacy of the 2 methods.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19249487     DOI: 10.1016/j.transproceed.2008.10.074

Source DB:  PubMed          Journal:  Transplant Proc        ISSN: 0041-1345            Impact factor:   1.066


  4 in total

1.  Characteristics of Circulating Donor Human Leukocyte Antigen-specific Immunoglobulin G Antibodies Predictive of Acute Antibody-mediated Rejection and Kidney Allograft Failure.

Authors:  Dinesh Kannabhiran; John Lee; Joseph E Schwartz; Rex Friedlander; Meredith Aull; Thangamani Muthukumar; Sean Campbell; David Epstein; Surya V Seshan; Sandip Kapur; Vijay K Sharma; Manikkam Suthanthiran; Darshana Dadhania
Journal:  Transplantation       Date:  2015-06       Impact factor: 4.939

2.  Histocompatibility testing for organ transplantation purposes in Albania: a single center experience.

Authors:  Erkena Shyti; Alma Idrizi; Genc Sulcebe
Journal:  Balkan Med J       Date:  2014-06-01       Impact factor: 2.021

3.  Impact of sensitivity of human leucocyte antigen antibody detection by Luminex technology on graft loss at 1 year.

Authors:  Peter Szatmary; James Jones; Abdul Hammad; Derek Middleton
Journal:  Clin Kidney J       Date:  2013-06

4.  Outcome after Desensitization in HLA or ABO-Incompatible Kidney Transplant Recipients: A Single Center Experience.

Authors:  Teresa Kauke; Sandra Klimaschewski; Ulf Schoenermarck; Michael Fischereder; Andrea Dick; Markus Guba; Manfred Stangl; Jens Werner; Bruno Meiser; Antje Habicht
Journal:  PLoS One       Date:  2016-01-05       Impact factor: 3.240

  4 in total