Literature DB >> 1924791

Comparison of Kaopectate with barium for negative and positive enteric contrast at MR imaging.

D G Mitchell1, S Vinitski, F B Mohamed, J F Mammone, K Haidet, M D Rifkin.   

Abstract

In an evaluation of safe, inexpensive, orally administered contrast agents for use at magnetic resonance imaging, different concentrations of the clay agents kaolin-pectate and attapulgite were compared in an in vitro phantom by performing spin-echo imaging with variable echo times to estimate T2 relaxation time. Additional phantoms containing from 0% to 100% attapulgite or barium preparations were compared by using spin-echo and spoiled-gradient-echo techniques to estimate T1, T2, and T2* relaxation times. In vivo spin-echo and gradient-echo images were obtained of 10 healthy volunteers and of five patients with pancreatic disease after oral administration of 12-16 oz of attapulgite preparation. T1 and T2 relaxation times obtained with use of attapulgite were slightly lower than those obtained with kaolin-pectate at both 50% and 25% concentrations. Compared with barium, attapulgite had shorter T1, T2, and T2* relaxation times, and concentration-dependent relaxivity was greater by nearly an order of magnitude. All subjects were able to drink the attapulgite, and the only complaints were of bad taste and mildly loose stools.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1924791     DOI: 10.1148/radiology.181.2.1924791

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Blueberry juice used per os in upper abdominal MR imaging: composition and initial clinical data.

Authors:  A H Karantanas; N Papanikolaou; J Kalef-Ezra; A Challa; N Gourtsoyiannis
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

2.  Pyrolytic graphite foam: a passive magnetic susceptibility matching material.

Authors:  Gary C Lee; Patrick W Goodwill; Kevin Phuong; Ben A Inglis; Greig C Scott; Brian A Hargreaves; Lizabeth Li; Alex C Chen; Rachana N Shah; Steven M Conolly
Journal:  J Magn Reson Imaging       Date:  2010-09       Impact factor: 4.813

3.  Retrograde air insufflation in MRI: a technical note.

Authors:  C K Chou; G C Liu; L T Chen; T S Jaw
Journal:  Abdom Imaging       Date:  1993

4.  Image artifacts on prostate diffusion-weighted magnetic resonance imaging: trade-offs at 1.5 Tesla and 3.0 Tesla.

Authors:  Yousef Mazaheri; H Alberto Vargas; Gregory Nyman; Oguz Akin; Hedvig Hricak
Journal:  Acad Radiol       Date:  2013-08       Impact factor: 3.173

Review 5.  MR imaging of the prostate in clinical practice.

Authors:  Yousef Mazaheri; Amita Shukla-Dave; Ada Muellner; Hedvig Hricak
Journal:  MAGMA       Date:  2008-09-16       Impact factor: 2.310

6.  Abdominal pseudotumors and simulated lymphadenopathy in MRI: differential features with the use of retrograde air insufflation.

Authors:  C K Chou; R S Sheu; C W Yang; M L Wang; L T Chen
Journal:  Abdom Imaging       Date:  1994 Nov-Dec