Blocking is an important step before an enzyme-linked immunosorbent assay (ELISA) can be performed. It reduces non-specific binding to the microtiter plate to a minimum. For detecting food allergens by means of ELISA, the problem with protein blocking solutions is obvious. The blocker might interfere with the antibodies of the assay and leads to false positive results. Therefore, other blocking solutions are greatly needed. There are some alternatives like synthetic blockers or carbohydrates. Comparisons of these different blocking agents, namely proteins, carbohydrates, and synthetic blockers, were made at different reaction conditions. The incubation periods and temperatures were varied, as well as the pH. The best combinations were evaluated and compared, in respect of their blocking efficiency. The two best non-proteinaceous blockers, i.e. polyvinylalcohol and Ficoll, were subsequently applied to ELISA tests for the determination of alpha-casein and peanut. The study showed that Ficoll and PVA did as well as BSA in buffer solution. Therefore, they can be considered as alternative blocking reagents for ELISA, especially for the detection of food allergens.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19247640     DOI: 10.1007/s00216-009-2698-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

1.  Solution of the problem of nonspecific binding in solid-phase noninstrumental dot immunoassay.

Authors:  M S Bochkova; V P Timganova; M B Raev
Journal:  Dokl Biochem Biophys       Date:  2013-05-09       Impact factor: 0.788

2.  Enzyme-linked immunosorbent assay (ELISA) and blocking with bovine serum albumin (BSA)--not all BSAs are alike.

Authors:  Yuhong Xiao; Stuart N Isaacs
Journal:  J Immunol Methods       Date:  2012-06-23       Impact factor: 2.303

Review 3.  Signal Improvement Strategies for Fluorescence Detection of Biomacromolecules.

Authors:  Chengxin Luan; Zixue Yang; Baoan Chen
Journal:  J Fluoresc       Date:  2016-04-11       Impact factor: 2.217

4.  Quantum dots assembly enhanced and dual-antigen sandwich structured lateral flow immunoassay of SARS-CoV-2 antibody with simultaneously high sensitivity and specificity.

Authors:  Jianghua Jia; Lijiao Ao; Yongxin Luo; Tao Liao; Liang Huang; Dinglv Zhuo; Chenxing Jiang; Jing Wang; Jun Hu
Journal:  Biosens Bioelectron       Date:  2021-11-17       Impact factor: 12.545

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.