Literature DB >> 19244697

Variations in endotracheal cuff pressure in intubated critically ill patients: prevalence and risk factors.

Saad Nseir1, Helene Brisson, Charles-Hugo Marquette, Pascal Chaud, Christophe Di Pompeo, Maimouna Diarra, Alain Durocher.   

Abstract

BACKGROUND AND
OBJECTIVE: An endotracheal cuff pressure of 20-30 cmH(2)O is recommended. Underinflation and overinflation are associated with complications such as aspiration and tracheal wall damage. The aim of this study was to identify prevalence of, and risk factors for, endotracheal cuff underinflation and overinflation.
METHODS: Prospective observational cohort study. All critically ill patients intubated with a high-volume lowpressure endotracheal tube were eligible. After manual adjustment of cuff pressure at 25 cmH(2)O, continuous recording of cuff pressure and airway pressure was performed for 8 h. Underinflation and overinflation of the endotracheal cuff were defined as cuff pressure less than 20 cmH(2)O and more than 30 cmH(2)O, respectively. In all patients, the time spent with normal cuff pressure or with underinflation or overinflation of the endotracheal cuff was measured. Univariate and multivariate analyses were used to determine risk factors for cuff underinflation and overinflation.
RESULTS: Eight hundred and eight hours of cuff pressure recordings were analysed in 101 patients. Eighteen per cent of study patients spent 100% of recording time with normal (20-30 cmH(2)O) cuff pressure. Fifty-four per cent of study patients developed cuff underinflation, 73% developed cuff overinflation, and 44% developed both. Thirty- three per cent of study patients developed underinflation or overinflation for more than 30 min. Absence of sedation [odds ratio (95% confidence interval)=2.51 (1-6), P=0.03] and duration of prior intubation [1.16 (1.04-1.29), P<0.01] were independently associated with cuff underinflation. No risk factor for overinflation could be determined. The percentage of time spent with underinflation significantly (P<0.01) increased during the recording period.
CONCLUSION: Variations in endotracheal cuff pressure are common in ICU patients. Duration of prior intubation and absence of sedation are independently associated with increased risk for cuff underinflation.

Entities:  

Mesh:

Year:  2009        PMID: 19244697     DOI: 10.1097/eja.0b013e3283222b6e

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  31 in total

1.  Variables affecting leakage past endotracheal tube cuffs: a bench study.

Authors:  Renée Pitts; Daniel Fisher; Demet Sulemanji; Joseph Kratohvil; Yandong Jiang; Robert Kacmarek
Journal:  Intensive Care Med       Date:  2010-09-18       Impact factor: 17.440

2.  Condensation of humidified air in the inflation line of a polyurethane cuff precludes correct continuous pressure monitoring during mechanical ventilation.

Authors:  Herbert Spapen; Walter Moeyersons; Wim Stiers; Geert Desmet; Emiel Suys
Journal:  J Anesth       Date:  2014-05-23       Impact factor: 2.078

Review 3.  Novel preventive strategies for ventilator-associated pneumonia.

Authors:  Andrea Coppadoro; Edward Bittner; Lorenzo Berra
Journal:  Crit Care       Date:  2012-12-12       Impact factor: 9.097

4.  The role of the endotracheal tube cuff in microaspiration.

Authors:  V Anne Hamilton; Mary Jo Grap
Journal:  Heart Lung       Date:  2011-12-30       Impact factor: 2.210

5.  Impact of polyurethane on variations in tracheal cuff pressure in critically ill patients: a prospective observational study.

Authors:  Saad Nseir; Farid Zerimech; Julien De Jonckheere; Isabelle Alves; Malika Balduyck; Alain Durocher
Journal:  Intensive Care Med       Date:  2010-04-16       Impact factor: 17.440

6.  Evaluation of an intervention to maintain endotracheal tube cuff pressure within therapeutic range.

Authors:  Mary Lou Sole; Xiaogang Su; Steve Talbert; Daleen Aragon Penoyer; Samar Kalita; Edgar Jimenez; Jeffery E Ludy; Melody Bennett
Journal:  Am J Crit Care       Date:  2011-03       Impact factor: 2.228

7.  The effect of mouth prop on endotracheal tube intracuff pressure in children during dental rehabilitation under general anaesthesia.

Authors:  Dilek Günay Canpolat; Kenan Cantekin; Adnan Bayram; Mustafa Denizhan Yıldırım
Journal:  J Clin Monit Comput       Date:  2017-01-20       Impact factor: 2.502

8.  The Professional Experience of Anaesthesiologists in Proper Inflation of Laryngeal Mask and Endotracheal Tube Cuff.

Authors:  Ayten Saraçoğlu; Didem Dal; Gökhan Pehlivan; Fevzi Yılmaz Göğüş
Journal:  Turk J Anaesthesiol Reanim       Date:  2014-07-09

9.  Endotracheal tube cuff pressure assessment maneuver induces drop of expired tidal volume in the postoperative of coronary artery bypass grafting.

Authors:  Douglas W Bolzan; Solange Guizilini; Sonia M Faresin; Antonio Cc Carvalho; Angelo Av De Paola; Walter J Gomes
Journal:  J Cardiothorac Surg       Date:  2012-06-10       Impact factor: 1.637

10.  The Association Between Endotracheal Tube Size and Aspiration (During Flexible Endoscopic Evaluation of Swallowing) in Acute Respiratory Failure Survivors.

Authors:  Gintas P Krisciunas; Susan E Langmore; Stephanie Gomez-Taborda; Daniel Fink; Joseph E Levitt; Jeffrey McKeehan; Edel McNally; Rebecca Scheel; Alix C Rubio; Jonathan M Siner; Rosemary Vojnik; Heather Warner; S David White; Marc Moss
Journal:  Crit Care Med       Date:  2020-11       Impact factor: 9.296

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.