Literature DB >> 19244062

Three-dimensional power Doppler vascular sonographic sampling for predicting ovarian cancer in cystic-solid and solid vascularized masses.

Juan Luis Alcázar1, David Rodriguez.   

Abstract

OBJECTIVE: The purpose of this study was to explore the role of 3-dimensional (3D) power Doppler (PD) sonography to discriminate between benign and malignant cystic-solid and solid vascularized adnexal masses and to define cutoff values for 3D PD indices to be used in a clinical setting.
METHODS: A total of 143 consecutive women (mean age, 50.4 years; range, 17-82 years) with diagnoses of cystic-solid or solid vascularized adnexal masses on B-mode and 2-dimensional PD sonography were evaluated by 3D PD sonography before surgery. Three-dimensional PD sonography was used to assess vascularization within papillary projections and solid areas with a virtual organ computer-aided analysis program. Three-dimensional PD vascular indices (vascularization index [VI], flow index [FI], and vascularization-flow index [VFI]) were automatically calculated. A definitive histologic diagnosis was obtained in each case.
RESULTS: A total of 113 masses (74%) were malignant, and 39 (26%) were benign. Morphologic evaluation revealed 30 unilocular solid masses (19.7%), 43 multilocular solid masses (28.3%), and 79 mostly solid masses (52%). The mean VI (9.365% versus 3.3%; P< .001), FI (34.318 versus 28.794; P< .001), and VFI (3.233 versus 1.15; P<0.01) were significantly higher in malignant tumors. No differences were found in the resistive index, pulsatility index, and peak systolic velocity. Receiver operating characteristic analysis revealed an area under the curve of 0.77 (95% confidence interval, 0.69-0.85), 0.71 (0.60-0.81), and 0.75 (0.66-0.83) for the VI, FI and VFI, respectively. For reducing the false-positive rate by almost one-third, sensitivity values for the VI (cutoff, 1.556%), FI (25.212), and VFI (0.323) were 92%, 95%, and 93%, respectively.
CONCLUSIONS: Three-dimensional PD vascular indices could be helpful for reducing the false-positive rate in cystic-solid and solid vascularized adnexal masses.

Entities:  

Mesh:

Year:  2009        PMID: 19244062     DOI: 10.7863/jum.2009.28.3.275

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

Review 1.  Role of Three-Dimensional Ultrasound in Gynecology.

Authors:  Engin Turkgeldi; Bulent Urman; Baris Ata
Journal:  J Obstet Gynaecol India       Date:  2014-11-08

2.  The role of 3-dimensional power Doppler imaging in the assessment of ovarian teratoma in pregnancy: a case report.

Authors:  Konstantinos Kalmantis; Christos Iavazzo; Vasiliki Anastasiadou; Aris Antsaklis
Journal:  Case Rep Med       Date:  2011-08-25

3.  Contrast-enhanced ultrasound in ovarian tumors - diagnostic parameters: method presentation and initial experience.

Authors:  Anita-Roxana Maxim; Radu Badea; Atilla Tamas; Alexandru Traila
Journal:  Clujul Med       Date:  2013-02-04

4.  Reliability of preoperative evaluation of postmenopausal ovarian tumors.

Authors:  Riikka Johanna Niemi; Sami Kristian Saarelainen; Tiina Hannele Luukkaala; Johanna Unelma Mäenpää
Journal:  J Ovarian Res       Date:  2017-03-14       Impact factor: 4.234

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.