Literature DB >> 19244053

Minimally invasive autopsy: an alternative to conventional autopsy?

Annick C Weustink1, M G Myriam Hunink, Cornelis F van Dijke, Nomdo S Renken, Gabriel P Krestin, J Wolter Oosterhuis.   

Abstract

PURPOSE: To determine the diagnostic performance of minimally invasive autopsy (MIA) for detection of causes of death and to investigate the feasibility of MIA as an alternative to conventional autopsy (CA) in the clinical setting.
MATERIALS AND METHODS: The institutional review board approved the MIA procedure and study, and informed consent was obtained for all deceased patients from relatives. Thirty deceased patients (19 men, 11 women; age range, 46-79 years), for whom family permission for CA on medical grounds had already been obtained, underwent additional evaluation with MIA prior to CA. MIA consisted of whole-body 16-section computed tomography (CT) and 1.5-T magnetic resonance (MR) imaging, followed by ultrasonography-guided 12-gauge needle biopsy of heart, both lungs, liver, both kidneys, and spleen. Percentage agreement between MIA and CA on cause of death was evaluated. Sensitivity and corresponding 95% confidence intervals (CIs) of MIA for detection of overall (major plus minor) findings, with CA as the reference standard, were calculated. Specificity was calculated for overall findings. Sensitivity analysis was performed to explore the effect of the clustered nature of the data.
RESULTS: In 23 patients (77%), MIA and CA were in agreement on the cause of death. Sensitivity of MIA for detection of overall findings and detection of major findings was 93% (95% CI: 90%, 96%) and 94% (95% CI: 87%, 97%), respectively. Specificity was 99% (95% CI: 98%, 99%) for detection of overall findings. MIA failed to demonstrate acute myocardial infarction as the cause of death in four patients. Sensitivity analysis indicated a negligible correlation between observations within each patient. CT was superior to MR for detection of pneumothorax and calcifications. MR was superior to CT for detection of brain abnormalities and pulmonary embolus. With biopsy only, detection of disease in 55 organs was possible, which included 27 major findings.
CONCLUSION: MIA is a feasible procedure with high diagnostic performance for detection of common causes of death such as pneumonia and sepsis; MIA failed to demonstrate cardiac diseases, such as acute myocardial infarction and endocarditis, as underlying cause of death. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/250/3/897//DC1. RSNA, 2009

Entities:  

Mesh:

Year:  2009        PMID: 19244053     DOI: 10.1148/radiol.2503080421

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  77 in total

1.  Virtual CT autopsy in clinical pathology: feasibility in clinical autopsies.

Authors:  Saskia E Westphal; Jonas Apitzsch; Tobias Penzkofer; Andreas H Mahnken; Ruth Knüchel
Journal:  Virchows Arch       Date:  2012-06-23       Impact factor: 4.064

2.  Nontraumatic postmortem computed tomographic demonstration of cerebral gas embolism following cardiopulmonary resuscitation.

Authors:  Seiji Shiotani; Yukihiro Ueno; Shigeru Atake; Mototsugu Kohno; Masatsune Suzuki; Kazunori Kikuchi; Hideyuki Hayakawa
Journal:  Jpn J Radiol       Date:  2010-01-30       Impact factor: 2.374

3.  [The supremacy of vision in medical diagnostics : Prof. Stefan Feuerbach's 65th birthday].

Authors:  B Dietl
Journal:  Radiologe       Date:  2011-01       Impact factor: 0.635

Review 4.  Post-mortem computed tomography angiography: past, present and future.

Authors:  Sarah L Saunders; Bruno Morgan; Vimal Raj; Guy N Rutty
Journal:  Forensic Sci Med Pathol       Date:  2010-12-12       Impact factor: 2.007

5.  Post mortem scientific sampling and the search for causes of death in intensive care: what information should be given and what consent should be obtained?

Authors:  J P Rigaud; J P Quenot; M Borel; I Plu; C Hervé; G Moutel
Journal:  J Med Ethics       Date:  2010-12-24       Impact factor: 2.903

6.  Postmortem CT versus forensic autopsy: frequent discrepancies of tracheobronchial content findings.

Authors:  Wolf-Dieter Zech; Christian Jackowski; Nicole Schwendener; Eva Brencicova; Frederick Schuster; Paolo Lombardo
Journal:  Int J Legal Med       Date:  2015-09-23       Impact factor: 2.686

7.  Comparison of diagnostic performance for perinatal and paediatric post-mortem imaging: CT versus MRI.

Authors:  Owen J Arthurs; Anna Guy; Sudhin Thayyil; Angie Wade; Rod Jones; Wendy Norman; Rosemary Scott; Nicola J Robertson; Thomas S Jacques; W K 'Kling' Chong; Roxanna Gunny; Dawn Saunders; Oystein E Olsen; Catherine M Owens; Amaka C Offiah; Lyn S Chitty; Andrew M Taylor; Neil J Sebire
Journal:  Eur Radiol       Date:  2015-10-21       Impact factor: 5.315

Review 8.  Advances in post-mortem CT-angiography.

Authors:  S Grabherr; J Grimm; A Dominguez; J Vanhaebost; P Mangin
Journal:  Br J Radiol       Date:  2014-04       Impact factor: 3.039

Review 9.  Postmortem imaging of sudden cardiac death.

Authors:  Katarzyna Michaud; Silke Grabherr; Christian Jackowski; Marc Daniel Bollmann; Franceso Doenz; Patrice Mangin
Journal:  Int J Legal Med       Date:  2013-01-16       Impact factor: 2.686

Review 10.  Current techniques in postmortem imaging with specific attention to paediatric applications.

Authors:  Tessa Sieswerda-Hoogendoorn; Rick R van Rijn
Journal:  Pediatr Radiol       Date:  2009-12-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.