Literature DB >> 19243054

Effect of superparamagnetic iron oxide on tumor-to-liver contrast at T2*-weighted gradient-echo MRI: comparison between 3.0T and 1.5T MR systems.

Tonsok Kim1, Takamichi Murakami, Masatoshi Hori, Hiromitsu Onishi, Kaname Tomoda, Hironobu Nakamura.   

Abstract

PURPOSE: To compare 3.0T and 1.5T MR systems in terms of the effect of superparamagnetic iron oxide (SPIO) on tumor-to-liver contrast in T2*-weighted gradient-echo MRI.
MATERIALS AND METHODS: SPIO-enhanced gradient-echo MR images of the liver with four different TEs (3, 5.3, 6.5, and 8.5 msec) were obtained by means of 1.5T and 3.0T systems. Quantitative analyses of relative signal intensities (SIs) and relative tumor contrast and qualitative analyses of image quality and lesion conspicuity of the liver were performed in 22 patients, 16 of whom had malignant liver tumors.
RESULTS: With both 1.5T and 3.0T, at TE=8.4 msec, the relative SI of liver and relative tumor contrast were significantly (P<0.01) lower and higher, respectively, than that for any of the other TEs. There were no significant differences in the relative SI of the liver, relative tumor contrast, image quality, and tumor conspicuity for the same TE between the 1.5T and 3.0T systems.
CONCLUSION: Our results showed that the effect of SPIO on tumor-to-liver contrast at T2*-weighted gradient-echo imaging was similar for the 1.5T and 3.0T systems, and that the 8.4-msec TE was optimal of the four TEs used in this study at 3.0T. Copyright (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19243054     DOI: 10.1002/jmri.21384

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Quality comparison between three-dimensional T2-weighted SPACE and two-dimensional T2-weighted turbo spin echo magnetic resonance images for the brachytherapy planning evaluation of prostate and periprostatic anatomy.

Authors:  Tharakeswara K Bathala; Aradhana M Venkatesan; Jingfei Ma; Priyadarshini Bhosale; Wei Wei; Rajat J Kudchadker; Jihong Wang; Mitchell S Anscher; Chad Tang; Teresa L Bruno; Steven J Frank; Janio Szklaruk
Journal:  Brachytherapy       Date:  2020-05-10       Impact factor: 2.362

2.  Detection of hepatic metastases by superparamagnetic iron oxide-enhanced MR imaging: prospective comparison between 1.5-T and 3.0-T images in the same patients.

Authors:  Keitaro Sofue; Masakatsu Tsurusaki; Mototaka Miyake; Aine Sakurada; Yasuaki Arai; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2010-04-29       Impact factor: 5.315

3.  Evaluation of the uptake function of liver in rats with obstructive jaundice before and after relief from obstruction by superparamagnetic iron oxide-enhanced magnetic resonance imaging.

Authors:  Zhou Yiming; Jiang Lei; Zhai Renyou; Ke Shan; Li Xue; Liu Min; Gao Jun
Journal:  Oncol Lett       Date:  2012-05-24       Impact factor: 2.967

Review 4.  GRE T2∗-weighted MRI: principles and clinical applications.

Authors:  Meng Yue Tang; Tian Wu Chen; Xiao Ming Zhang; Xiao Hua Huang
Journal:  Biomed Res Int       Date:  2014-04-16       Impact factor: 3.411

5.  The applied research of simultaneous image acquisition of T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) in the assessment of patients with prostate cancer.

Authors:  Yi Liu; Wei Wang; Xiu-Bo Qin; Hui-Hui Wang; Ge Gao; Xiao-Dong Zhang; Xiao-Ying Wang
Journal:  Asian J Androl       Date:  2019 Mar-Apr       Impact factor: 3.285

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.