Tiny ferromagnetic intraocular foreign bodies detected by magnetic resonance imaging: a report of two cases.

Yong Zhang1, Jingliang Cheng, Jie Bai, Cuiping Ren, Yan Zhang, Xuemei Gao, Xiaolin Cui, Yun Jun Yang.   

Abstract

We report two cases with tiny ferromagnetic intraocular foreign bodies (FBs) that were demonstrated only on magnetic resonance imaging (MRI) and confirmed by subsequent ophthalmologic operation. Both of the patients had a history of ocular trauma and their clinical symptoms were compatible with an intraocular FB. Plain x-ray film, 3 mm slice thickness computed tomography (CT) scans (Toshiba TXT 600 system and GERP22 system), B-scan ultrasonography, and an MRI study (Siemens Impact 1.0 MR system) were acquired. MR examinations were performed using spin-echo (SE) T1, T2, and PD-weighted axial and sagittal or coronal images with 3 mm slice thickness. Plain x-ray film, 3 mm slice thickness CT scans and B-scan ultrasonography all failed to demonstrate any tiny intraocular FBs in these two patients, whereas MRI revealed tiny ferromagnetic FBs due to their characteristic magnetic susceptibility artifact. A ferromagnetic FB was found in the vitreous body of each patient, which were 0.375x0.3x0.15 mm and 0.5x0.4x0.2 mm, respectively, and there was no evidence of MR-induced damage. We suggest that tiny ferromagnetic fragments with a diameter below 0.5 mm, which are too small to be visualized by x-ray plain films and CT images, may be visualized on MR images. These tiny ferromagnetic particles may not be large enough to cause ocular damage during a 1.0T MRI examination. MRI may be a useful tool in the evaluation of tiny intraocular ferromagnetic FBs if other imaging modalities such as plain s-ray, CT scan, and ultrasonography failed to do so. Further evaluation with a large-scale study (in vitro and in vivo animal study) for the safety of detecting tiny (<0.5 mm) intraocular ferromagnetic particles is warranted. Copyright (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19243045     DOI: 10.1002/jmri.21637

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Metallic intraocular foreign body as detected by magnetic resonance imaging without complications- A case report.

Authors:  Alexander S Platt; Benjamin G Wajda; April D Ingram; Xing-Chang Wei; Anna L Ells
Journal:  Am J Ophthalmol Case Rep       Date:  2017-06-22

2.  Penetrating ocular trauma associated with blank cartridge.

Authors:  Sunghyuk Moon; Su-Ho Lim
Journal:  BMC Ophthalmol       Date:  2014-03-03       Impact factor: 2.209

3.  Characteristics of wooden intraocular foreign body by magnetic resonance imaging in rabbits.

Authors:  Baohong Wen; Jingliang Cheng; Huixia Zhang; Yong Zhang; Xiaonan Zhang; Chenyu Yan; Fengguang Zhang
Journal:  J Int Med Res       Date:  2018-10-01       Impact factor: 1.671

4.  A 3-year review of MRI safety incidents within a UK independent sector provider of diagnostic services.

Authors:  Darren Hudson; Andrew P Jones
Journal:  BJR Open       Date:  2019-04-30