Literature DB >> 19242933

Performance of five different electrospray ionisation sources in conjunction with rapid monolithic column liquid chromatography and fast MS/MS scanning.

Karl E V Burgess1, Alex Lainson, Lisa Imrie, Douglas Fraser-Pitt, Raja Yaga, David G E Smith, Remco Swart, Andrew R Pitt, Neil F Inglis.   

Abstract

The performances of five different ESI sources coupled to a polystyrene-divinylbenzene monolithic column were compared in a series of LC-ESI-MS/MS analyses of Escherichia coli outer membrane proteins. The sources selected for comparison included two different modifications of the standard electrospray source, a commercial low-flow sprayer, a stainless steel nanospray needle and a coated glass Picotip. Respective performances were judged on sensitivity and the number and reproducibility of significant protein identifications obtained through the analysis of multiple identical samples. Data quality varied between that of a ground silica capillary, with 160 total protein identifications, the lowest number of high quality peptide hits obtained (3012), and generally peaks of lower intensity; and a stainless steel nanospray needle, which resulted in increased precursor ion abundance, the highest-quality peptide fragmentation spectra (5414) and greatest number of total protein identifications (259) exhibiting the highest MASCOT scores (average increase in score of 27.5% per identified protein). The data presented show that, despite increased variability in comparative ion intensity, the stainless steel nanospray needle provides the highest overall sensitivity. However, the resulting data were less reproducible in terms of proteins identified in complex mixtures -- arguably due to an increased number of high intensity precursor ion candidates.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19242933     DOI: 10.1002/pmic.200800200

Source DB:  PubMed          Journal:  Proteomics        ISSN: 1615-9853            Impact factor:   3.984


  3 in total

1.  Performance comparisons of nano-LC systems, electrospray sources and LC-MS-MS platforms.

Authors:  Qian Liu; Jennifer S Cobb; Joshua L Johnson; Qi Wang; Jeffrey N Agar
Journal:  J Chromatogr Sci       Date:  2013-01-17       Impact factor: 1.618

2.  Proteomic characterisation of the Chlamydia abortus outer membrane complex (COMC) using combined rapid monolithic column liquid chromatography and fast MS/MS scanning.

Authors:  David Longbottom; Morag Livingstone; Kevin D Aitchison; Lisa Imrie; Erin Manson; Nicholas Wheelhouse; Neil F Inglis
Journal:  PLoS One       Date:  2019-10-24       Impact factor: 3.240

3.  Proteomic and genomic analysis reveals novel Campylobacter jejuni outer membrane proteins and potential heterogeneity.

Authors:  Eleanor Watson; Aileen Sherry; Neil F Inglis; Alex Lainson; Dushyanth Jyothi; Raja Yaga; Erin Manson; Lisa Imrie; Paul Everest; David G E Smith
Journal:  EuPA Open Proteom       Date:  2014-06-26