Literature DB >> 19242832

Pulsed magnetohydrodynamic blood flow in a rigid vessel under physiological pressure gradient.

Dima Abi-Abdallah1, Agnès Drochon, Vincent Robin, Odette Fokapu.   

Abstract

Blood flow in a steady magnetic field has been of great interest over recent years. Many researchers have examined the effects of magnetic fields on velocity profiles and arterial pressure, and major studies have focused on steady or sinusoidal flows. In this paper, we present a solution for pulsed magnetohydrodynamic blood flow with a somewhat realistic physiological pressure wave obtained using a Windkessel lumped model. A pressure gradient is derived along a rigid vessel placed at the output of a compliant module which receives the ventricle outflow. Then, velocity profile and flow rate expressions are derived in the rigid vessel in the presence of a steady transverse magnetic field. As expected, results showed flow retardation and flattening. The adaptability of our solution approach allowed a comparison with previously addressed flow cases and calculations presented a good coherence with those well established solutions.

Entities:  

Mesh:

Year:  2009        PMID: 19242832     DOI: 10.1080/10255840802687384

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  1 in total

1.  Comparison of three artificial models of the magnetohydrodynamic effect on the electrocardiogram.

Authors:  Julien Oster; Raul Llinares; Stephen Payne; Zion Tsz Ho Tse; Ehud Jeruham Schmidt; Gari D Clifford