Literature DB >> 19242054

The use of gel dosimetry to measure the 3D dose distribution of a 90Sr/90Y intravascular brachytherapy seed.

G Massillon-Jl1, R Minniti, M G Mitch, M J Maryanski, C G Soares.   

Abstract

Absorbed dose distributions in 3D imparted by a single (90)Sr/(90)Y beta particle seed source of the type used for intravascular brachytherapy were investigated. A polymer gel dosimetry medium was used as a dosemeter and phantom, while a special high-resolution laser CT scanner with a spatial resolution of 100 microm in all dimensions was used to quantify the data. We have measured the radial dose function, g(L)(r), observing that g(L)(r) increases to a maximum value and then decreases as the distance from the seed increases. This is in good agreement with previous data obtained with radiochromic film and thermoluminescent dosemeters (TLDs), even if the TLDs underestimate the dose at distances very close to the seed. Contrary to the measurements, g(L)(r) calculated through Monte Carlo simulations and reported previously steadily decreases without a local maximum as a function of the distance from the seed. At distances less than 1.5 mm, differences of more than 20% are observed between the measurements and the Monte Carlo calculations. This difference could be due to a possible underestimation of the energy absorbed into the seed core and encapsulation in the Monte Carlo simulation, as a consequence of the unknown precise chemical composition of the core and its respective density for this seed. The results suggest that g(L)(r) can be measured very close to the seed with a relative uncertainty of about 1% to 2%. The dose distribution is isotropic only at distances greater than or equal to 2 mm from the seed and is almost symmetric, independent of the depth. This study indicates that polymer gel coupled with the special small format laser CT scanner are valid and accurate methods for measuring the dose distribution at distances close to an intravascular brachytherapy seed.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19242054     DOI: 10.1088/0031-9155/54/6/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Monte Carlo dosimetric parameter study of a new (32)P brachytherapy source.

Authors:  Junxiang Wu; Jing Huang; Fengxiang Long; Chengkai Wang; Zhangwen Wu; Chengjun Gou
Journal:  Br J Radiol       Date:  2016-04-04       Impact factor: 3.039

2.  Pilot Study of Polymerization Dynamics in nMAG Dose Gel.

Authors:  Mantvydas Merkis; Benas Gabrielis Urbonavicius; Diana Adliene; Jurgita Laurikaitiene; Judita Puiso
Journal:  Gels       Date:  2022-05-06

3.  A novel thin NIPAM gel cassette dosimeter for photon-beam radiotherapy.

Authors:  Ling-Ling Hsieh; Kai-Yuan Cheng; Bor-Tsung Hsieh
Journal:  PLoS One       Date:  2012-03-12       Impact factor: 3.240

Review 4.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28

Review 5.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

6.  Whole Three-Dimensional Dosimetry of Carbon Ion Beams with an MRI-Based Nanocomposite Fricke Gel Dosimeter Using Rapid T1 Mapping Method.

Authors:  Shinya Mizukami; Yusuke Watanabe; Takahiro Mizoguchi; Tsutomu Gomi; Hidetake Hara; Hideyuki Takei; Nobuhisa Fukunishi; Kenichi L Ishikawa; Shigekazu Fukuda; Takuya Maeyama
Journal:  Gels       Date:  2021-11-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.